Specifications
Typical for 25 °C unless otherwise specified.
Specifications in
italic text
are guaranteed by design.
Analog input section
Table 1. Analog input specifications
Parameter Conditions Specification
A/D converter type
16-bit successive Approximation type
Number of channels
8 single-ended
Input configuration
Individual A/D per channel
Sampling method
Simultaneous
Absolute maximum input voltage
CHx IN to GND.
±15 V max
Input impedance
100 MOhm, min
Input ranges
Software selectable
±10 V, ±5 V, ±2 V, ±1 V
Scan to PC memory
0.6 S/s to 50 kS/s, software
programmable
Sampling rate
Burst scan to 32 k sample FIFO
20 S/s to 50 kS/s, software
programmable
Software paced
500 S/s all channels
Scan to PC memory (Note 1)
= (100 kS/s) / (# of channels), max of
50 kS/s for any channel
Throughput
Burst scan to 32 k
sample FIFO
= (200 kS/s) / (# of channels), max of
50 kS/s for any channel
Gain queue
Software configurable. Eight elements,
one gain element per channel.
Resolution
16 bits
No missing codes
15 bits
Crosstalk
Signal DC-25 KHz
-80 dB
CAL output
User calibration source
0.625 V, 1.25 V, 2.5 V, 5.0 V, software
selectable
CAL output accuracy (Note 2)
±0.5% typ, ±1.0% max
CAL current
±5 mA max
Trigger source
Software selectable External
digital:
TRIG_IN
Note 1:
Maximum throughput scanning to PC memory is machine dependent. While the majority of XP
equipped PC’s we tested allowed acquisition at the maximum rates, a few would not. The lowest
maximum rate we observed on an XP equipped PC during multi-channel testing was 95 kS/s,
aggregate. The rates specified are for Windows XP only. Maximum rates on operating systems that
predate XP may be less and must be determined through testing on your machine.
Note 2:
Actual values used for calibration are measured and stored in EEPROM.