Rev. 1.2E
Manual ME-63Xtend Series
Specifications
Page 44
Meilhaus Electronic
Recommended Operating Conditions
Conditions: U
b
=5V±10%, T
A
=25°C
Static Values
Conditions: U
b
=5V±10%, T
A
=25°C
Dynamic Values
Conditions: U
b
=5V±10%, T
A
=25°C
Measurement Values Test Conditions
MIN
Typ
MAX
Unit
Operating voltage U
b
5
V
Output voltage U
out
12
280
V
AC,rms
Output current I
out
time unlimited, all channels
(without forced ventilation)
60
4000
mA
AC,rms
Output current I
out
time unlimited, maximum
each second channel in ope-
ration, (without forced
ventilation)
60
5000
mA
AC,rms
Measurement Values
Test Conditions MIN
Typ
MAX
Unit
U
in,H
3,5
U
b
+ 0,6
V
U
in,L
1,5
V
I
in,H
U
in
=3,85V
0,93
1,35
mA
Voltage drop at output
U
out
=U
out,max
1,4
V
AC
Measurement Values Test Conditions MIN
Typ
MAX
Unit
f
in
1
VAC cycle
t
pd,on
0,5
VAC cycle
t
pd,off
0,5
VAC cycle
cos
ϕ
Maximum load
0,5
1