Operating instructions WasteStar CC
9717376
Design and construction subject to change without prior notice!
Page
18
of
36
8.2
Switching on and working with the WasteStar CC
DANGER
Risk of fatal electrical shock or fatal injuries caused by rotating parts!
Operate the device with completely closed casing only. Before removing any clad-
ding, the on-site mains electricity supply must be switched off and secured with a
padlock to prevent it from being switched back on. Otherwise there's the risk of fatal
injury!
Switch on the locally available power disconnection unit.
Press the on/off button to switch on the machine. This launches a control check of
the safety equipment.
After approximately 10 seconds press the button on/off again. The Power key per-
manently lights up in blue. The system is on now.
Initial filling:
Feed in approximately 10 litres of liquid as the initial fill!
In case of raw organic waste (raw fruit/vegetables): 15 litres.
Feed kitchen waste and leftovers into the funnel.
If required, add water for rinsing off.
Press the grinder on button. The grinder on button permanently lights up in blue.
The comminuting process takes approximately 5 minutes and stops automatically.
The grinder on button no longer lights up permanently.
Press the grinder on button for approx. 3 sec. The grinder on button permanently
lights up in blue.
The comminuting process takes approximately 60 minutes and stops automatically.
The grinder on button no longer lights up permanently.
8.3
Draining comminuted waste
The pump starts automatically once the grinder tank reaches maximum filling level
to pump out waste for 8 seconds.
Simultaneously the brinder unit is also active.
9
Cleaning and switching off the system
WARNING
Material damage
The installation, switch cabinets and other electrical components must NOT be sprayed
with a hose or a high pressure cleaner.!
Avoid flooding the base of the system to prevent damage to components from penetrat-
ing water!
Содержание WasteStar CC
Страница 36: ......