VN2700R PocketRef-Final1012011
www.meigroup.com For Technical Support Call: 1-800-345-8172
•
Calibration Procedure
1.
Apply power to the VN2700R. The rear display will read
2.
To access the Setup menu, press and hold the “SELECT” button for 3 seconds
or until flashes.
3.
Within 2 seconds
, press and hold “MODE” until
(Load)
begins to flash.
4.
Press and release the “MODE” button 3 times until
(Setup)
appears.
5.
Press the “SELECT” button.
(recycled bill)
will appear.
6.
Press the “MODE” button 6 times until the display shows (Profile)
7.
Press the “Select” button. (Calibrate) will appear.
8.
Press the “Select” button again and will blink rapidly.
►
You are now ready to calibrate the VN2700R.
◄
9.
Insert the Calibration paper supplied with the unit.
(ONLY insert the Calibration paper. DO NOT insert a bill or coupon.)
The Calibration paper will be drawn into the Recycler and then ejected in a
series of steps as calibration takes place. In a few more seconds, the unit
will reset with a “run and stack” action. After calibration, the rear display
will show “0” indicating the Recycler is currently empty and ready for use
.
10. Calibration is now complete!
•
Remove the set back spacer from the bezel before installation. The spacer is
only used on select snack machines and will often cause interference issues with
beverage machines.
•
Make sure the Recycler is mounted flush against the front panel, without any
cable or mechanical interference. Particularly, look for screws or studs that are
too long. NOTHING can press on the recycler in any way. Even the slightest
pressure will misalign it and cause it to fail. Use configuration coupon (CP mode)
to set the recycler to accept $10's and or $20's. The default from the factory
accepts $1's & $5's.
•
The Capacity (CA) is set to 25 from the factory.
•
Set the Recycled bill (rb) to $1 or $5. Factory default is $1.
•
Set Interface Level (IF) to the appropriate setting. L3 is the default. Set to L2 if
accepting up to $20’s. Set to
rE
if operating in MDB revision 4 mode.
•
The Accept Inhibit (AI) Option can be set to “Yes”. When set to “Yes”, the
recycler will inhibit acceptance of high-value bills if it cannot payout the majority
of change in bills. This prevents the changer from being emptied out by a single
transaction.
Note: If your VN2700 was manufactured prior to week 48, 2009, you
will need to send your Bill Validator to an Authorized Service Center to
be upgraded with a Recycler Module. If your VN2700 has the Recycler
Ready Symbol on the label, your VN2700 can be upgraded in the field.
1.
Make sure power to the vending machine is OFF.
2.
Remove Bill Cassette.
3.
Disconnect and remove “Y” MDB cable.
(This cable is not used with the Recycler.)
4.
Remove the VN2700 from the vending Machine.
5.
Remove the Black Rain Shield by pressing a screwdriver in the bottom slot and
sliding the cover up. Install the new Rain Shield. Slide it down until it snaps into
place. (The difference between the two shields is that the new one has the edge
filed off so that the new 30-pin connector from the Recycler will fit.)
6.
Remove bottom LED Housing – Pull up the
metal bar and remove the housing from the
chassis. Disconnect the 8-pin cable going to
the VN2700 control board.
7.
Insert Recycler module. Make sure it clicks into place.
(Pull back on the Recycler to ensure it locked into place.)
8.
Connect Recycler harness to the FRONT of the Bill
Validator using the 30-pin connector.
9.
Connect the 8-pin connector between Recycler and
the SIDE of the bill validator, (where the bottom of
the LED housing was connected.)
10.
Connect the 6-pin Male MDB COINMECH ONLY cable to the coin changer.
(NEVER connect a device between the coin changer and the VN2700R.)
11.
Connect the 6-pin Female MDB connector to the Vending Machine Controller.
12.
Double check connections and then apply power to the vending machine.
13.
If the MODE/SELECT display on the back of the VN2700R is ON, you are
ready to proceed to the Calibration Procedure. If the display is not on,
double check for loose connections.
1.
You MUST have the Bill Programming Module (BPM)
programmed with the latest Recycler code.
-
Power Down the Vending Machine’s Payment Systems -
2.
Disconnect the MDB connector that supplies
power and communication to the Recycler.
3.
Connect BPM connector in between the Recycler and the
machine. (There is no connection to the 30-pin BPM
connector. This is for service center use only.)
4.
Power up the machine. Recycler display will power up
normally, and the
RED
and
GREEN
LEDs on the BPM
will begin to Flash. NOTE: Programming will take
about 8 minutes to complete. DO NOT interrupt
this process or you will have to restart the process
from the beginning. DO NOT turn off the power and
DO NOT unplug any cables while the BPM programs
the Recycler.
5.
The unit will start to download software to the Recycler
from the BPM as indicated by the “Double Flash” of the
GREEN
LED. Unit will display
6.
A “Constant Flash” of the
GREEN
LED indicates that the unit is downloading
software to the Bill Validator. Unit will display
7.
When programming is complete, the unit will do a complete Reset, followed by
a normal Run and Stack. The
GREEN
LED will remain “Constant ON”.
NOTE: If at any time the
RED
and
GREEN
LEDs flash in an alternating
fashion, there is a problem with the programming cycle and it needs to
start over. To start over, turn OFF the machine power,
count to five, then turn ON the machine power.
8.
When programming is complete, power OFF the machine
and disconnect the BPM.
9.
Reconnect Recycler to the machine and then power ON
the machine.
VN2700R Software update is complete!
VN2700 Upgrade to VN2700R
Upgrading Software
VN2700 Upgrade to VN2700R
(continued)
FRONT
(30 Pin)
SIDE
(8 Pin)
Sample VNR Installation Check List
0
BP
AP
Recycler Ready Symbol
Ld
SU
rb
Pr
CL
–
–
CL
LED
Housing