background image

VN2700R PocketRef-Final1012011  

 

 

 

 

 

 

 

www.meigroup.com        For Technical Support Call:  1-800-345-8172

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calibration Procedure 

1.

 

Apply power to the VN2700R. The rear display will read 

             

2.

 

To access the Setup menu, press and hold the “SELECT” button for 3 seconds 

or until            flashes. 

 

3.

 

Within 2 seconds

, press and hold “MODE” until            

(Load)

 begins to flash. 

 

4.

 

Press and release the “MODE” button 3 times until            

(Setup)

 appears.  

 

5.

 

Press the “SELECT” button.            

(recycled bill)

 will appear. 

 

6.

 

Press the “MODE” button 6 times until the display shows           (Profile)  

 

7.

 

Press the “Select” button.            (Calibrate) will appear. 

8.

 

Press the “Select” button again and            will blink rapidly.

 

 

 

         

You are now ready to calibrate the VN2700R. 

 

9.

 

  Insert the Calibration paper supplied with the unit. 

 

      (ONLY insert the Calibration paper. DO NOT insert a bill or coupon.) 

 

The Calibration paper will be drawn into the Recycler and then ejected in a 

series of steps as calibration takes place. In a few more seconds, the unit 

will reset with a “run and stack” action. After calibration, the rear display 

will show “0” indicating the Recycler is currently empty and ready for use

.  

   

10. Calibration is now complete! 

 

 

 

 

Remove the set back spacer from the bezel before installation. The spacer is 

only used on select snack machines and will often cause interference issues with 

beverage machines.  

 

Make sure the Recycler is mounted flush against the front panel, without any 

cable or mechanical interference. Particularly, look for screws or studs that are 

too long. NOTHING can press on the recycler in any way. Even the slightest 

pressure will misalign it and cause it to fail. Use configuration coupon (CP mode) 

to set the recycler to accept $10's and or $20's. The default from the factory 

accepts $1's & $5's.  

 

The Capacity (CA) is set to 25 from the factory.   

 

Set the Recycled bill (rb) to $1 or $5.  Factory default is $1. 

 

Set Interface Level (IF) to the appropriate setting. L3 is the default. Set to L2 if 

accepting up to $20’s. Set to 

rE

 if operating in MDB revision 4 mode. 

 

The Accept Inhibit (AI) Option can be set to “Yes”. When set to “Yes”, the 

recycler will inhibit acceptance of high-value bills if it cannot payout the majority 

of change in bills. This prevents the changer from being emptied out by a single 

transaction. 

 

 

 

 

 

 

Note: If your VN2700 was manufactured prior to week 48, 2009, you 

will need to send your Bill Validator to an Authorized Service Center to 

be upgraded with a Recycler Module. If your VN2700 has the Recycler 

Ready Symbol on the label, your VN2700 can be upgraded in the field. 

 

1.

 

Make sure power to the vending machine is OFF

2.

 

Remove Bill Cassette. 

3.

 

Disconnect and remove “Y” MDB cable. 

(This cable is not used with the Recycler.) 

4.

 

Remove the VN2700 from the vending Machine. 

5.

 

Remove the Black Rain Shield by pressing a screwdriver in the bottom slot and 

sliding the cover up. Install the new Rain Shield. Slide it down until it snaps into 

place. (The difference between the two shields is that the new one has the edge  

filed off so that the new 30-pin connector from the Recycler will fit.) 

6.

 

Remove bottom LED Housing – Pull up the  

metal bar and remove the housing from the  

chassis. Disconnect the 8-pin cable going to 

the VN2700 control board. 

 

  

 

7.

 

Insert Recycler module. Make sure it clicks into place. 

(Pull back on the Recycler to ensure it locked into place.) 

 

 

 

8.

 

Connect Recycler harness to the FRONT of the Bill  

Validator using the 30-pin connector.  

 

 

9.

 

Connect the 8-pin connector between Recycler and  

the SIDE of the bill validator, (where the bottom of 

the LED housing was connected.) 

 

 

 

10.

 

Connect the 6-pin Male MDB COINMECH ONLY cable to the coin changer. 

   

(NEVER connect a device between the coin changer and the VN2700R.)

 

11.

 

Connect the 6-pin Female MDB connector to the Vending Machine Controller. 

12.

 

Double check connections and then apply power to the vending machine. 

13.

 

If the MODE/SELECT display on the back of the VN2700R is ON, you are  

 ready to proceed to the Calibration Procedure. If the display is not on,  

 double check for loose connections. 

 

 

 

 

1.

 

You MUST have the Bill Programming Module (BPM)  

programmed with the latest Recycler code.

 

 

 - 

Power Down the Vending Machine’s Payment Systems - 

 

 

2.

 

Disconnect the MDB connector that supplies  

power and communication to the Recycler. 

 

 

3.

 

Connect BPM connector in between the Recycler and the 

machine. (There is no connection to the 30-pin BPM  

connector. This is for service center use only.) 

 

 

4.

 

Power up the machine. Recycler display will power up  

normally, and the 

RED

 and 

GREEN

 LEDs on the BPM 

will begin to Flash. NOTE: Programming will take

 

 about 8 minutes to complete. DO NOT interrupt 

 

this process or you will have to restart the process

 

 from the beginning. DO NOT turn off the power and

 

DO NOT unplug any cables while the BPM programs

 

 the Recycler. 

 

 

  

 

5.

 

The unit will start to download software to the Recycler  

from the BPM as indicated by the “Double Flash” of the 

GREEN

 LED. Unit will display  

 

6.

 

A “Constant Flash” of the 

GREEN

 LED indicates that the unit is downloading 

software to the Bill Validator. Unit will display 

 

7.

 

When programming is complete, the unit will do a complete Reset, followed by 

a normal Run and Stack. The 

GREEN

 LED will remain “Constant ON”. 

 

NOTE: If at any time the 

RED

 and 

GREEN

 LEDs flash in an alternating 

fashion, there is a problem with the programming cycle and it needs to 

start over. To start over, turn OFF the machine power,  

count to five, then turn ON the machine power. 

 

8.

 

When programming is complete, power OFF the machine  

and disconnect the BPM. 

 

9.

 

Reconnect Recycler to the machine and then power ON  

the machine. 

 

VN2700R Software update is complete!

 

 

 

 

 

VN2700 Upgrade to VN2700R 

 

Upgrading Software 

 

VN2700 Upgrade to VN2700R 

(continued)

 

 

FRONT 

(30 Pin)

 

SIDE 

(8 Pin)

 

Sample VNR Installation Check List 

 

BP 

AP 

Recycler Ready Symbol 

Ld 

SU 

rb 

Pr 

CL 

 

– 

CL 

LED  

Housing 