3

3. 3.2 channel characteristics set

MTC-04 buffer (BFM) channel characteristics set as table 3-6

Table 3-6 MTC-04-NTR buffer (BFM) channel characteristics set

BFM

Content

Remarks

Nat

ure

Sa

ve

CH1 CH2 CH3 CH4

#200

Restore

factory

setting*1

Default value

0 R/W

N

#201

Change

Settings

allowed*2

Default value

1

Allows to change

0

Not Allowed

To Change

R/W

N

#801 #802 #803 #804

Digital filter

set of one

step

Default value

0

Range

0

100

Seconds

R/W

Y

#809 #810 #811 #812 D0*3

Default value

0 R/W

Y

#817 #818 #819 #8209 D1*3

Default value

12000

With the

input type

change

R/W

Y

#825 #826 #827 #828 A0*3

Default value

0

R

N

#833 #834 #835 #836 A1*3

Default value

12000

With the input

type change

R

N

* 1. After #200 is set to 1, all BFM units of the module are reset to their

default values.
* 2. Change Settings allowed for BFM. Setting BFM#201 to 0 will

prevent the user from making inadvertent adjustments to BFM. Once

the disable Settings feature is set, it remains in effect until the allow

command is set (#201 = 1).
* 3. #801 ~ #804: set the data cache D0 for each channel; #809 ~ #812:

each channel feature sets the data cache D1. Use the two-point

method to set channel characteristics, D0, D1 represents the channel

output digital quantity, A0, A1 represents the channel actual input

temperature value, each channel occupies 4 words. Considering the

convenience of the user's setting, and without affecting the realization

of the function, A0 was fixed as 0

, and A1 was fixed as the maximum

of the measurement range in the current mode. If you change the D0

and D1 values of the channel, you can change the channel

characteristics. D0 and D1 can be adjusted

±

1000 on the basis of

factory setting. If the current mode USES Celsius, the adjustment range

is

±

100

; if the current mode USES Fahrenheit, the adjustment

range is

±

100

. If a value is set beyond this range, the MTC will not

accept it and will keep the original valid setting.

3. 3.3 control function setting

MTC-04-NTR buffer (BFM) set the control function of the content to

table 3-7.

Table 3-7 MTC-04 buffer (BFM) the control function of the set

BFM

Content

Remarks

Natu

re

Sa

ve

CH1 CH2 CH3 CH4

#901 #902 #903 #904 Input type *1 Default value

0 R/W

Y

#909 #910 #911 #912 Set value

(SV) * 2

Default value

0.0

Unit

0.1

/

R/W

Y

#917 #918 #919 #920 Proportional

cycle time* 3

Default value

2

Range

1

100 R/W

Y

#925 #926 #927 #928

Heat side

proportional

band

Default value

30

Unit

0.1

Range

0.1

%~

1000.0

R/W

Y

#933 #934 #935 #936

Heat side int

egral time

Default value

240

Range

1

3600

Seconds

R/W

Y

#941 #942 #943 #944

Heat side

Derivative

time

Default value

60

Range

0

3600

Seconds

R/W

Y

BFM

Content

Remarks

Natu

re

Sa

ve

CH1 CH2 CH3 CH4

#957 #958 #959 #960

Cool side

proportional

band

Default value

30

Unit

0.1

Range

0.1

%~

1000.0

R/W

Y

#965 #966 #967 #968

Cool side int

egral time

Default value

240

Range

1

3600

Seconds

R/W

Y

#973 #974 #975 #976

Cool side

derivative

time

Default value

60

Range

0

3600

Seconds

R/W

Y

#981 #982 #983 #984 Overlap/dead

band*4

Default value

0

No overlapped

non-inductive

belt

Setting

range:-input

range~+input

range

R/W

Y

#989 #990 #991 #992

Undershoot

suppression

factor*5

Water-cooled

default

Air-cooled

default

Range:0~1000

R/W

Y

#997

Run/stop

transfer of

CH1-CH4 *6

Default value

B0000

0

Stop 1

Start

R/W

Y

M0

M1

M2

M3

Run/stop

transfer of

CH1-CH4 *6

Default value

B0000

0

Stop 1

Start

R/W

Y

#999

Auto-tuning

setting of

CH1- CH4 *7

Default value

B0000

0:Not self-tuning

or auto-tuning h

as been

completed

1

Auto-Tune

R/W

Y

M8

M9

M10 M11

Auto-tuning

setting of

CH1- CH4 *7

Default value

0

0:Not self-tuning

or auto-tuning h

as been

completed

1

Auto-Tune

R/W

Y

#100

0

#100

1

#100

2

#100

3

Run/stop

transfer of

CH1-CH4 *6

Default value

2

0

Hand 1

ON/OFF 3:PID

R/W

Y

#100

8

#100

9

#101

0

#101

1

Heat/Cool

action*8

Default value

1

0:Cooling

1:Heating

2:Heating and

cooling (air

cooling)

3:Heating and

cooling (water

cooling)

4:Position ratio

PID

R/W

Y

#101

6

#101

7

#101

8

#101

9

Hand output

value

Default value

0

Range

0.0

100.0

(%)

R/W

Y

#102

4

#102

5

#102

6

#102

7

Adjust

sensitivity

ON/OFF

control

method is

effective

Default

value:100

Unit

0.1

/

Range

0~999

R/W

Y

BFM

Content

Remarks

Nat

ure

Sa

ve

CH1 CH2 CH3 CH4

#103

2

#103

3

#103

4

#103

5

Auto-tuning

deviation

Default value

0

Unit

0.1

/

Range:

±

input

range

R/W

Y

#110 #110 #110 #110 Heat side

Default value

R/W

Y