Meggitt Fuelling Products
Maintenance Manual (MMF251)
Hydrant Coupler – F251 Series
USE OR DISCLOSURE OF DATA ON THIS PAGE IS SUBJECT TO THE RESTRICTIONS ON THE TITLE PAGE OF THIS DOCUMENT
28 Feb 2014
Revision 4.0
12
INSPECTION
1. General
A. Under strong light and magnification, Look at all parts in accordance with the general criteria
specified in
Table 4
.
B. Repair minor damage in accordance with local directives. If damage is major or beyond simple
repair, replace the part.
2. Component
Checks
(Refer to
Table 4
)
Table 4
Component Checks
DESCRIPTION CHECK
CRITERIA
General
Look at all parts as applicable for nicks, cracks, cuts, burrs, corrosion,
breaks, scoring, chafing, scarring, deformation, dents, thread damage,
or any other obvious defects. Make sure the ports, passages, recesses
and sealing grooves are clean and are not blocked.
Make sure all sealing and seating surfaces are free from damage or
corrosion.