Megger VF5 Скачать руководство пользователя страница 4

www.megger.com

Product Name

4

Battery replacement

1.  Carefully unscrew battery cap at the rear (torch end) of 

the detector.

2.  Replace batteries with 2 x AAA 1.5V batteries. Observe 

polarity.

3.  Carefully align cap with detector as shown above.

4.  Screw cover onto the detector until it feels tight; do 

not use excessive force.

5.  Verify operation by using the detector on a known live 

AC voltage within the defined detection range of the 
detector.

 

Note

: When batteries are loaded for the first time, 

please remove the white rectangular security strip before 
installing.

When replacing the batteries, be sure to secure the cap 
firmly to maintain IP67 water and dust protection. A loose 
or over tightened battery cap may compromise water and 
dust protection.

Specifications

Detection voltage range 

12 V AC to 1000 V AC,  

 

 

 

 

100 V to 1000 V AC

Frequency range 

 

50/60 Hz

Batteries 

 

 

2 x AAA / LR03 1.5 V

Ambient Operating temperature 
 

 

 

 

0 °C to 50 °C 

 

 

 

 

(32 °F to 122 °F)

Storage temperature   

-10 °C to 60 °C  

 

 

 

 

(14 °F to 140 °F)

Humidity 

 

 

80 % max.

Altitude 

  2000 

meters

Pollution Degree 

 

2

Safety Compliance 

 

CAT IV 1000 V

Auto Power Off 

 

5 minutes

Ingress Protection Rating 

IP67

Product manufactured in China

Maintenance

Do not attempt to repair this detector. It contains no user-
serviceable parts.

Repair or servicing should only be performed by qualified 
personnel.

Cleaning

Periodically wipe the case with a dry cloth and detergent, 
do not use abrasives or solvents.

WEEE Directive

The crossed out wheeled bin symbol on the instrument and 
on the batteries is

a reminder not to dispose of them with general waste at 
the end of their life.

Megger is registered in the UK as a Producer of Electrical 
and Electronic equipment. The registration No is; WEE/
DJ2235XR.

Users of Megger products in the UK may dispose of 
them at the end of their useful life by contacting B2B 
Compliance at www.b2bcompliance.org.uk or by 
telephone on 01691 676124.

Users of Megger products in other regions should contact 
their local Megger office or distributor.

Отзывы: