REPAIR AND WARRANTY

The instrument circuit contains static sensitive devices, and care must be taken
in handling the printed circuit board. If the protection of an instrument has
been impaired it should not be used, and be sent for repair by suitably trained
and qualified personnel. The protection is likely to be impaired if, for example,
the instrument shows visible damage, fails to perform the intended measure-
ments, has been subjected to prolonged storage under unfavourable conditions,
or has been exposed to severe transport stresses.

New Instruments are Guaranteed for 3 Years from the 

Date of Purchase by the User

Note:

Any unauthorized prior repair or adjustment will automatically

invalidate the Warranty.

Instrument Repair and Spare Parts

For service requirements for Megger

®

Instruments contact :-

Megger Limited 

or

Megger

Archcliffe Road   

Valley Forge Corporate Center

Dover 

2621 Van Buren Avenue

Kent,  CT17 9EN

Norristown, PA 19403

England

U.S.A.

Tel:  +44 (0) 1304 502243

Tel:  +1 (610) 676-8579

Fax: +44 (0) 1304  207342   

Fax: +1 (610) 676-8625 

or an approved repair company.

Returning an Instrument for Repair

If it is necessary to retun an instrument for repair, a Returns Authorisation
number must first be obtained by contacting one of the addresses shown.
You will be asked to provide key information, such as the instrument serial
number and fault reported when the number is issued. This will enable the
Service Department to prepare in advance for the receipt of your instrument,
and to provide the best possible service to you.

The Returns Authorisation number should be clearly marked on the outside
of the product packaging, and on any related correspondence. The
instrument should be sent, freight paid to the appropriate address. If
appropriate a copies of the original purchase invoice and of the packing note,
should be sent simultaneously by airmail to expedite clearance through
customs.

For instruments requiring repair outside the warranty period a repair
estimate will be submitted to the sender, if required, before work on the
instrument commences.

Approved Repair Companies

Megger operates fully traceable repair and calibration facilities complemented
by a network of approved repair and calibration companies, to offer excellent
in-service care for your Megger products. Megger’s streamlined Returns
Authorization system ensures your product is expected and enables you to
track its progress on-line.

Содержание MIT415

Страница 1: ...NSW 2125 Australia T 61 0 2 9659 2005 F 61 0 2 9659 2201 E ausales megger com Megger Limited 110 Milner Avenue Unit 1 Scarborough Ontario M1S 3R2 Canada T 1 416 298 9688 Canada only T 1 416 298 6770...

Страница 2: ...M MIT415 Insulation and continuity tester User Guide...

Страница 3: ...f it is damaged n All test leads probes and crocodile clips must be in good order clean and with no broken or cracked insulation n Ensure that hands remain behind guards of probes clips when testing n...

Страница 4: ...st lead probes also observe voltage discharges to a safe level On battery cover see section 2 0 notes 10 and 11 At terminals do not exceed rated input voltage t Equipment protected throughout by Doubl...

Страница 5: ...re both AC and DC components of the supply voltage AC DC In DC mode only the DC component is measured 1 Rotate selector switch to the V position 2 Connect test leads to the circuit under test 3 Press...

Страница 6: ...displayed on the secondary display 5 The insulation test can be locked on by pressing the lock button whilst holding down the TEST button To disable lock press the TEST button or lock button 6 By pres...

Страница 7: ...a test result is stored t1 After 10 minutes a second test result is stored t2 The resultant ratio is then displayed on the screen The same procedure applies for the DAR timed tests however the test du...

Страница 8: ...ent firmware revision is displayed followed by the buzzer alarm threshold Displayed Meaning Default Setting symbol setting options BUZ Set top threshold for continuity buzzer in ohms 2 1 2 5 10 20 Buz...

Страница 9: ...r and lift out the cells Ensure that the replacement cells are fitted with the correct polarity in accordance with the label in the battery compartment Replace and re secure the battery compartment co...

Страница 10: ...t on load 1 mA at min pass value of insulation specified in BS7671 HD384 and IEC364 EN61152 2 2 mA max EN61557 operating range 0 10 M to 1 00 G Leakage current range 10 A to 2000 A Leakage current 10...

Страница 11: ...r Operates at 25 volts a c or d c on any range except OFF Frequency 15 400Hz 15Hz 99 9Hz 0 5 1 digit 100Hz to 400Hz Power supply 5 x 1 5V cells type IEC LR6 AA MN1500 HP7 AM3 R6HP Alkaline NiMH rechar...

Страница 12: ...ture range 30 C to 80 C Calibration Temperature 20 C Maximum altitude 2000 m Dust and water protection IP54 Accessories Includes accessories 2 wire test lead set and crocodile clips 6220 813 SP5 Remot...

Страница 13: ...t is necessary to retun an instrument for repair a Returns Authorisation number must first be obtained by contacting one of the addresses shown You will be asked to provide key information such as the...

Страница 14: ......

Отзывы: