background image

CONTENTS

SAFETY WARNINGS

1

FEATURES DESCRIPTION

3

CONTROLS DESCRIPTION

4

LIQUID CRYSTAL DISPLAY

5

OPERATING INSTRUCTIONS

6

Ground Resistance Measurement

6

High and Low Alarm (

)

8

Ground/Leakage Current Measurement

8

Setting the Sampling Interval

8

Data Logging

8

Downloading Data to a PC (DET20C only)

8

Format of Down Loaded Data (DET20C only)

9

Reading the Data Stored in Memory

9

Clearing the Data Memory

9

Enable RS-232C output (DET20C only)

10

Installation of Megger Download Manager Software

10

Description of Megger Download Manager Software

10

PRINCIPLE OF OPERATION

11

ELECTRICAL SPECIFICATION

13

GENERAL SPECIFICATIONS

14

ACCESSORIES

14

BATTERY REPLACEMENT

15

2

Содержание DET10C

Страница 1: ...M DET10C and DET20C Clamp on Ground Resistance Tester User Manual...

Страница 2: ...und tester to twist or pry the ground electrode or ground wire away from the equipment being grounded All metal objects or wires connected to the electrical system should be assumed to be lethal until...

Страница 3: ...ng Interval 8 Data Logging 8 Downloading Data to a PC DET20C only 8 Format of Down Loaded Data DET20C only 9 Reading the Data Stored in Memory 9 Clearing the Data Memory 9 Enable RS 232C output DET20C...

Страница 4: ...esistance tester enables the user to measure the ground resistance of a ground rod without the use of auxiliary ground rods The clamp on ground resistance tester is used in multi grounded systems with...

Страница 5: ...CD panel 5 REC button Function dependant on mode Starts either data logging single measurement recording or data download to PC Also used to increment a value in conjunction with FUNC button 6 FUNC bu...

Страница 6: ...Indicates ground resistance tester senses noise or excessive current present in the ground electrode 7 Jaw Open Displayed if the jaws are opened during the measurement this symbol and word OPEN will b...

Страница 7: ...amping around the ground electrode NOTE If self calibration does not complete The instrument will continue the process until a successful self calibration is achieved 1 Check the jaw mating surfaces I...

Страница 8: ...ction is disabled The HI or LO value can be disabled individually NOTE The HI value cannot be lower than the LO value Similarly the LO value cannot be higher than the HI value HI value will be adjuste...

Страница 9: ...REC will be shown on the LCD Data will be recorded at the specified sampling interval Data logging will be stopped if the memory is full or the unit detects a low battery condition or the REC button...

Страница 10: ...tion OPEN Jaws open NS Noise HI Hi alarm LO Low alarm HD Data Hold LB Battery low Example of down loaded data 0001 sampling time 10 00 ohm 10 02 ohm 5 200 ohm LO 1 000 ohm NS 1 500 mA 9 00 A NOTE Each...

Страница 11: ...putted every 0 5 seconds NOTE The RS 232C output is automatically disabled if data logging is in progress Installation of Megger Download Manager Software DET20C The DET20C instrument is supplied as s...

Страница 12: ...plified typical ground distribution system The equivalent circuit is shown in Figure A If R1 R2 R3 Rn are simplified to Req then only Rg and Req are left in the circuit refer to Figure B If a constant...

Страница 13: ...12 Rg Rg Req R1 R1 R2 R2 R3 R3 Rn Rn Figure A Figure B...

Страница 14: ...and Low Alarm Range Resolution High Alarm 0 1550 1 Lo Alarm 0 1550 1 Ground Leakage Current Auto range 50 60 Hz True RMS Crest Factor 3 5 Range Resolution Accuracy of Reading 0 200 1 000 mA 0 001 mA 2...

Страница 15: ...Down 5 minutes approx Sampling Time 0 5 seconds Operating Temperature 0 C to 50 C 14 F to 122 F Operating Humidity Less than 85 RH Storage Temperature 20 C to 60 C 4 F to 122 F Storage Humidity Less t...

Страница 16: ...ery with a new battery Remove instrument from test piece during battery change 1 Turn the switch to the OFF position 2 Unfasten the battery cover screw 3 Lift and remove the battery cover 4 Remove the...

Страница 17: ...unauthorized prior repair or adjustment will automatically invalidate the Warranty Instrument Repair and Spare Parts For service requirements for Megger Instruments contact Megger Limited or Megger Ar...

Страница 18: ...APPES France T 33 1 30 16 08 90 F 33 1 34 61 23 77 OTHER TECHNICAL SALES OFFICES Toronto CANADA Sydney AUSTRALIA Madrid SPAIN Mumbai INDIA and the Kingdom of BAHRAIN Megger products are distributed in...

Отзывы: