M
AVTMDELTA4000-EN Rev 6 April 2018
28
Operation
Test Mode
DELTA 4000 offers a quick setting for available test modes.
The top line (UST-R in this case) defines and describes the selected test mode.
The second and third lines explain how the instrument is configured for the
measurement. They have a different designation depending on if UST
(Ungrounded Specimen Test) or GST (Grounded Specimen Test) measurements
are conducted.
UST mode
Ground and Guard are internally connected. Red and Blue terminals are either
internally connected to be measured or internally connected to Ground (and
Guard). In UST mode, the center line refers to the terminal or terminals that are
measured and the lower line refers to the terminal that is internally connected to
Ground and therefore excluded from the measurement.
GST mode
The current returning from Ground is measured. The Red and Blue terminals are
either connected to Ground to be included in measurement or Guard to be
excluded from the measurement.