background image

Continuity Testing (

)

(

BM80/2

&

BM81/2

only)

The continuity tests are activated when the
probes make contact. The test operates
without the need to press the TEST button.
When the test leads are removed the reading
will hold for a few seconds and then reset.
This range is not suitable for diode testing
since the automatic contact detector will not be
activated when connected to a diode. The k

range can be used for diode testing.

1.

Set the selector switch to 

.

2.

Connect the test leads. The pointer will 
appear when connection to <10 M

is 

made.

3.

The test will activate automatically.

4.

After the test probes are disconnected, the 
reading will be held for a few seconds.

Continuity Bleeper (       )
(

BM80/2

&

BM81/2 

only)

The continuity bleeper sounds continuously
when less than 5 

is detected. Short bleeps

will sound for resistances lower than a few k

and above 5 

. If contact to less than 5 

is

maintained for five seconds, the bleeper stops,
and the display shows the measured
resistance.

1.

Set the selector switch to  

.

2.

Connect the test leads.

Zeroing of Test Lead Resistance 
(

BM80/2

&

BM81/2

only)

The resistance of the test leads can be nulled
on the continuity ranges. To zero the
resistance (up to 9,99 

), short the test leads

together, wait for a stable reading, and press
the TEST button. The symbol      will appear to
indicate the zero has been adjusted.

1.

Select either Continuity range.

2.

Short the test leads across a known good 
conductor.

3.

When the reading has stabilized, press the 
TEST button. A short ‘bleep’ will sound 
and the zero offset symbol will appear.

4.

To release the zero offset press the test 
button again or switch the instrument off.

8

Содержание BM80/2 Series

Страница 1: ...M BM80 2 Series Multi Voltage Insulation and Continuity Tester User Guide Guide de l utilisateur Gebrauchsanleitung Gu a del usuario...

Страница 2: ...tinuity Bleeper 8 Zeroing of Test Lead Resistance 8 Resistance Tests k 9 Voltage Tests V 9 Live Circuit Warning 9 Battery Check 10 Battery Replacement 10 Fuse Checking and Replacement 10 Application N...

Страница 3: ...llowed to discharge before disconnecting the test leads The Live Circuit Warning and Automatic Discharge are additional safety features and should not be regarded as a substitute for normal safe worki...

Страница 4: ...all electrical work so as to identify potential sources of electrical danger and risk of electrical injury such as from inadvertent short circuits Where the assessments show that the risk is significa...

Страница 5: ...trument enables the optional Megger SP6F Switched probe to be used for two handed probe operation The TEST button is used to initiate the insulation tests for operating the null facility and for adjus...

Страница 6: ...is nearly exhausted the symbol appears on the display Remaining battery life can be monitored at any time using the battery check switch position This is beneficial before going on site to ensure enou...

Страница 7: ...n test switch positions and after 5 minutes of instrument inactivity in all other switch positions If desired the 5 minute shut off can be changed to 60 minutes non insulation test switch positions To...

Страница 8: ...ur on subsequent tests 1 Set the selector switch to the test voltage required 2 Connect the test leads first to the instrument and then to the isolated item under test 3 Press the TEST button to activ...

Страница 9: ...uity bleeper sounds continuously when less than 5 is detected Short bleeps will sound for resistances lower than a few k and above 5 If contact to less than 5 is maintained for five seconds the bleepe...

Страница 10: ...V The presence of negative d c is indicated by dc on the display but no reading is given If the voltmeter operation is in question test the voltmeter on a known source 1 Set the selector switch to V...

Страница 11: ...the battery compartment cover in place Remove the cover and lift out the cells Ensure that the replacement cells are fitted with the correct polarity in accordance with the label in the battery compa...

Страница 12: ...esses all of which can arise on most industrial or utility equipment Insulation tests are sometimes used in isolation as absolute measures of the quality of the insulation This is most appropriate whe...

Страница 13: ...tion becomes charged up to the applied voltage 2 Absorption current This current is also initially high but drops at a much slower rate than the charging current 3 Conduction or Leakage current This i...

Страница 14: ...e current builds up quickly to a steady value and then remains constant for a particular applied voltage under stable conditions It is this current that is affected by moisture dirt etc and the degree...

Страница 15: ...digits 0 4 per G 250 V 50 G 2 2 digits 0 8 per G 100 V 20 G 2 2 digits 2 0 per G 50 V 10 G 2 2 digits 4 0 per G Notes All ranges measure from 0 00 M upwards 0 10 G on analogue scale on all ranges Test...

Страница 16: ...o 10 M on analogue scale Accuracy 3 2 digits Open circuit voltage 5 V 1 V Short circuit current 20 A 5 A Voltage Analogue Scale Measurement Accuracy 1 V 0 to 500 V Range 0 to 450 V d c or a c 50 60 Hz...

Страница 17: ...y E M C In accordance with IEC 61326 including amendment No 1 Interference Error caused by 50 60 Hz hum Insulation ranges 100 k to 10 error with 100 A rms Continuity range 0 2 to 50 3 error with 1 V r...

Страница 18: ...Glass fuses MUST NOT be fitted Power Supply Six LR6 Alkaline Cells Zinc carbon cells are not recommended Dimensions 220 x 92 x 50 mm Weight 625g Cleaning Wipe with a clean cloth dampened with soapy wa...

Страница 19: ...Typical Terminal Voltage Characteristics 18 BM80 2 BM82 2 only...

Страница 20: ...2 User Guide 6172 188 Optional Fused lead set FPK8 6111 218 Zip up carrying case 6420 132 Download Base DLB2 6420 602 Switch Test Probe SP6F 6220 836 Miniature A C Current Transducer MCC10 6111 290 Te...

Страница 21: ...ntact Megger LImited Archcliffe Road Dover Kent CT17 9EN Tel 44 0 1304 502243 England Fax 44 0 1304 207342 OR Megger Valley Forge Corporate Center 2621 Van Buren Avenue Norristown PA 19403 Tel 1 610 6...

Страница 22: ...21...

Страница 23: ...22 M BM80 2 Series Appareil de Contr le d isolement et continuit tensions multiples Guide de l utilisateur...

Страница 24: ...30 Mesure de continuit 30 Avertisseur de continuit 30 Remise z ro de la r sistance des cordons de mesure 31 Mesures de r sistance k 31 Mesures de tension V 31 Avertissement de circuit sous tension 32...

Страница 25: ...dons de mesure L avertissement de circuit sous tension et la d charge automatique sont des caract ristiques suppl mentaires de s curit et ne doivent pas tre consid r es comme rempla ant les pratiques...

Страница 26: ...verrouillable Une exploitation mains libres est possible sur toutes les gammes mises part les gammes d isolement Des soins particuliers doivent tre pris lorsque le bouton verrouillable est mont Symbo...

Страница 27: ...dessus de l instrument permet l utilisation de la sonde commut e optionnelle Megger SP6F pour une op ration deux mains Le bouton TEST est utilis pour initier les mesures d isolement la commande de fo...

Страница 28: ...presque d charg es le symbole appara t sur l affichage La dur e de vie restante des piles peut tre v rifi e tout moment l aide de l interrupteur de contr le des piles Cette fonction est pratique par e...

Страница 29: ...t automatique se d clenche pr c d e d une s rie de bips sonores apr s 12 minutes d inactiv de l instrument dans toutes les positions d essai d isolement ou apr s 5 minutes d inactivit dans toutes les...

Страница 30: ...harge capacitive sera indiqu e sur le voltm tre d avertissement de circuit sous tension Lorsque la gamme 1 kV est s lectionn e BM80 2 BM82 2 seulement et que le bouton TEST est appuy un d lai de s cur...

Страница 31: ...t activ es lorsque la sonde entre en contact La mesure est effectu e sans avoir appuyer sur le bouton TEST Lorsque les cordons de mesure sont retir s la lecture reste affich e pendant quelques seconde...

Страница 32: ...lecture est stable appuyer sur le bouton TEST Un bip de courte dur e retentit et le symbole de d calage de z ro appara t 4 Pour annuler le d calage de z ro appuyer de nouveau sur le bouton TEST ou ar...

Страница 33: ...ui seront disponibles jusqu ce que la tension d passe 55 V Note Si le fusible de 500 mA est grill le voltm tre continue fonctionner pour des tensions sup rieures 100 V 50 Hz Contr le des piles L instr...

Страница 34: ...i ce dernier ne va pas tre utilis pendant une longue p riode V rification et remplacement du fusible Pour v rifier le fusible de l instrument s lectionner une gamme d isolement et appuyer sur le bouto...

Страница 35: ...alis es qui peuvent toutes se produire sur la plupart des quipements industriels ou utilitaires Les mesures d isolement sont parfois utilis es seules pour donner une mesure absolue de la qualit de l i...

Страница 36: ...ialement lev puis chute au fur et mesure de la charge de l isolement la tension appliqu e 2 Courant d absorption Ce courant est aussi initialement lev mais chute beaucoup plus lentement que le courant...

Страница 37: ...ment Il est essentiellement fonction de la nature du mat riau isolant Le courant de conduction ou de fuite augmente rapidement pour atteindre une valeur uniforme qui reste constante pour une tension a...

Страница 38: ...V 50 G 2 2 chiffres 0 8 par G 100 V 20 G 2 2 chiffres 2 0 par G 50 V 10 G 2 2 chiffres 4 0 par G Notes Toutes les gammes mesurent partir de 0 00 M 0 10 G sur l echelle analogue dans toutes les gammes...

Страница 39: ...0 10 M sur chelle analogue Pr cision 3 2 chiffre Tension en circuit ouvert 5 V 1 V Courant de court circuit 20 A 5 A Tension chelle analogue Mesure Pr cision 1 V 0 500 V Gamme 0 450 V c c ou c a 50 60...

Страница 40: ...326 incluant l amendment No 1 Interf rence Erreur caus e par un bourdonnement de 50 60 Hz Gammes d isolement 100 k 10 d erreur avec 100 A efficace Gammes de continuit 0 2 50 3 d erreur avec 1 V effica...

Страница 41: ...iles alcalines LR6 Les piles zinc carbone ne sont pas recommand es Dimensions 220 x 92 x 50 mm Poids 625g Nettoyage Essuyer avec un chiffon doux propre tremp dans de l eau savonneuse ou de l alcool is...

Страница 42: ...Caract ristiques types de tension de borne 41 BM80 2 BM82 2 seulement...

Страница 43: ...r 6172 188 Optionnels Jeu de cordons de mesure avec fusible FPK8 6111 218 Bo tier de transport fermeture clair 6420 132 Base de t l chargement DLB 6420 602 Sonde d essai commut e SP6F 6220 836 Transdu...

Страница 44: ...nd pendantes de reparation d instruments ont t agr es pour faire des op rations de r paration sur la plupart des instruments Megger utilisant des pi ces d origine Megger Consultez le distributeur d si...

Страница 45: ...44 M BM80 2 Serie Mehrfachspannungs Isolations und Durchgangspr fer Gebrauchsanleitung...

Страница 46: ...s 51 Durchgangspr fung 52 Durchgangsanzeigeton 53 Nullstellen des Pr fkabelwiderstands 53 Widerstandspr fungen k 53 Spannungspr fungen V 53 Warnung vor stromf hrendem Stromkreis 54 Batterie berpr fung...

Страница 47: ...n Stromkreis und bei der automatischen Entladevorrichtung handelt es sich um zus tzliche Sicherheitsvorkehrungen die nicht als Ersatz f r eine normale undsichere Arbeitsweise verstanden werden d rfen...

Страница 48: ...rs Das Ger t kann bei allen Me bereichen au er bei der Isolationsmessung ohne st ndigen Gebrauch der H nde bedient werden Wenn der feststellbare Schalter eingebaut wird mu mit erh hter Vorsicht vorgeg...

Страница 49: ...en Das Verfahren zum Einschieben des Testschalters wird auf dem mit den Schaltern gelieferten separaten Anleitungsblatt erl utert ber einen auf den Kunden zugeschnittenen Verbinder an der Oberseite de...

Страница 50: ...wird mit Hilfe von sechs 1 5 V Alkalibatterien betrieben deren Kapazit t st ndig berwacht wird Wenn die Batterien ann hernd ersch pft sind erscheint auf der Anzeige das Symbol Durch Einstellen des Sc...

Страница 51: ...len Schalterstellungen zur Isolationspr fung wenn das Ger t 12 Minuten lang nicht in Betrieb ist nach einer Reihe von Warnt nen Bei allen anderen Schalterstellungen erfolgt die Abschaltung bereits nac...

Страница 52: ...eter f r den stromf hrenden Stromkreis wird der kapazitive Ladungsabfall angezeigt Wenn der Bereich von 1 kV gew hlt wird nur bei BM80 2 und BM82 2 und der TEST Schalter gedr ckt wird findet aus Siche...

Страница 53: ...en von Megger Limited die auf der Zubeh rseite aufgelistet sind Durchgangspr fung nur bei BM80 2 und BM81 2 Die Durchgangspr fungen werden aktiv sobald die F hler in Kontakt kommen F r diese Pr fung m...

Страница 54: ...Anzeige stabilisiert und TEST Schalter dr cken Er erscheint das Symbol wodurch angezeigt wird da die Nullposition eingestellt worden ist 1 Einen der Durchgangbereiche w hlen 2 Pr fkabel ber ein Kabel...

Страница 55: ...terie berpr fung automatisch auf Spannungsmessung um Zus tzlich ert nt bei allen Schalterpositionen au er OFF und V ein akustisches Warnsignal Alle gew hlten berpr fungen werden unterbunden mit Ausnah...

Страница 56: ...tteriefachs wieder einsetzen und befestigen Wenn das Ger t f r l ngere Zeit nicht benutzt wird m ssen die Batterien herausgenommen werden berpr fung und Austausch der Sicherung Zum berp fen der Sicher...

Страница 57: ...ungs belastung k nnen bei den meisten industriellen oder sonstigen Anlagen auftreten Die Isolationspr fungen werden zuweilen f r sich alleine genommen als absoluter Ma stab f r die Qualit t der Isolie...

Страница 58: ...flie ende Strom setzt sich aus drei verschiedenen Str men zusammen 1 Kapazitiver Ladestrom Dieser Strom besitzt zu Beginn eine hohe St rke welche abf llt wenn die Isolierung mit der angelegten Spannu...

Страница 59: ...bsorptionsstrom sinkt im Vergleich zum Ladestrom relativ langsam ab Grunds tzlich ist die Art des Isoliermaterials ausschlaggebend Der Leitungs oder Verluststrom baut sich z gig bis zu einem stabilen...

Страница 60: ...4 pro G 250 V 50 G 2 2 Stellen 0 8 pro G 100 V 20 G 2 2 Stellen 2 0 pro G 50 V 10 G 2 2 Stellen 4 0 pro G Hinweise Alle Bereiche beginnen die Messung bei 0 00 M als unterem Wert 0 10 G auf der analoge...

Страница 61: ...s zu 9 99 Akustisches Signal wird aktiviert bei unter ca 5 Widerstands Messung 0 1 k bis 100 k 0 10 M auf Analogskala Genauigkeit 3 2 Stellen Spannung bei unterbrochenem Stromkreis 5 V 1 V Stromst rke...

Страница 62: ...hne gesonderte gesicherte Pr fkabel Falls erforderlich sind gesicherte Pr fkabel als optionales Zubeh r erh ltlich Elektromagnetische St rfreiheit Entspricht IEC61326 inkl nderung Nr 1 Interferenz Von...

Страница 63: ...n rucht angepa t Werden Stromversorgung sechs LR6 Alkalibatterien Zink Kohle Batterien sind nicht zu empfehlen Abmessungen 220 x 92 x 50 mm Gewicht 625g Reinigung mit einem mit Seifenwasser oder Isopr...

Страница 64: ...Charakteristika einer typischen Anschlu spannung 63 nur bei BM80 2 und BM82 2...

Страница 65: ...atz mit Sicherungen FPK8 6111 218 Tragetasche mit Rei verschlu 6420 132 Downloadbasis DLB 6420 602 Schaltbarer Me f hler SP6F 6220 836 Miniatur Wechselstromwandler MCC10 6111 290 Pr faufzeichnungskart...

Страница 66: ...rwendung von Original Megger Ersatzteilen autorisiert Wenden Sie sich wegen Ersatzteilen Reparaturwerkstatten und Beratung ber die jeweils bestgeeigneten Ma nahmen an eine autorisierte Auslieferung bz...

Страница 67: ...66 M Serie BM80 2 Probador de aislamiento y continuidad de voltaje multiple Gu a del Usuario...

Страница 68: ...uidad 74 Avisador ac stico de continuidad 74 Puesta a cero de la resistencia del conductor de prueba 75 Pruebas de resistencia k 75 Pruebas de voltaje V 75 Aviso de circuito conrriente 76 Comprobaci n...

Страница 69: ...es de prueba El aviso del circuito con corriente y la descarga autom tica son caracter sticas adicionales de seguridad y no deben ser consideradas como un sustituto para la pr ctica normal de trabajo...

Страница 70: ...bloqueante Se incluye funcionamiento sin manos en todas las gamas excepto en las gamas de aislamiento Si se instala un bot n de prueba bloqueante deber n adoptarse precauciones adicionales S mbolos us...

Страница 71: ...la hoja de instrucciones separada incluida con los botones de prueba Un conector adaptado a los requerimientos del cliente situado en la parte superior del instrumento permite usar la sonda de interr...

Страница 72: ...ya vida til es constantemente vigilada Cuando la energ a de la bater a est casi agotada el s mbolo aparece en el display La vida til remanente en la bater a puede ser vigilada en cualquier momento usa...

Страница 73: ...cedida de un serie de avisos ac sticos se activa despu s de 12 minutos de inactividad del instrumento en todas las posiciones del interruptor de pruebas de aislamiento y despu s de 5 minutos de inacti...

Страница 74: ...o y el descenso de la carga capacitiva ser visualizado en el volt metro de aviso de circuito con corriente Cuando se ha seleccionado la gama de 1 kV s lo BM80 2 y BM82 2 y se ha pulsado el bot n de TE...

Страница 75: ...tinuidad s lo BM80 2 y BM82 2 Las pruebas de continuidad son activadas cuando las sondas hacen contacto La prueba funciona sin necesidad de pulsar el bot n de TEST Cuando se retiran los conductores de...

Страница 76: ...dad 2 Cortocircuite los conductores de prueba a trav s de un buen conductor conocido 3 Cuando se estabiliza la lectura pulse el bot n de TEST El avisador ac stico emitir un sonido corto y se visualiza...

Страница 77: ...as las pruebas seleccionadas ser n inhibidas excepto las pruebas de aislamiento de 100V y superiores las cuales se mantendr n disponibles hasta que el voltaje excede 55V Nota Si se ha fundido el fusib...

Страница 78: ...er odo de tiempo prolongado Comprobaci n y recambio del fusible Para comprobar el fusible del instrumento cambie a una gama de aislamiento y pulse el bot n de TEST El s mbolo aparece si el fusible est...

Страница 79: ...ad y tensiones de voltaje concentradas excesivas todas las cuales pueden experimentarse en la mayor a de los equipos industriales y utilitarios Las pruebas de aislamiento se usan a veces por s solas c...

Страница 80: ...rende tres corrientes separadas 1 Corriente de carga capacitiva Esta corriente es inicialmente alta y desciende a medida que se carga el aislamiento al voltaje aplicado 2 Corriente de absorci n Esta c...

Страница 81: ...on lentitud relativa comparada con la corriente de carga Esencialmente ello depender de la naturaleza del material aislante La corriente de conducci n o fuga se acumula r pidamente a un valor uniforme...

Страница 82: ...0 4 por G 250 V 50 G 2 2 d gitos 0 8 por G 100 V 20 G 2 2 d gitos 2 0 por G 50 V 10 G 2 2 d gitos 4 0 por G Notas Todas las gamas miden de 0 00 M para arriba 0 10 G en la escala anal gica en todas las...

Страница 83: ...ta 9 99 del conductor Avisador ac stico Se activa a menos de 5 aprox Resistencia Medici n 0 1 k a 100 k 0 a 10 M en la escala anal gica Precisi n 3 2 d gitos Voltaje en circuito abierto 5 V 1 V Corrie...

Страница 84: ...rovistos de fusibles separados Si se requieren los conductores de prueba provistos de fusibles se ofrecen disponibles como accesorios opcionales C E M Conforme a IEC61326 incluyendo enmienda No 1 Inte...

Страница 85: ...sibles de cristal Suministro el ctrico Seis pilas alcalinas LR6 Pilas de carbono de cinc no se recomiendan Dimensiones 220 x 92 x 50mm Peso 625g Limpieza Limpie con un trapo limpio humedecido en agua...

Страница 86: ...Caracter sticas de voltaje de bornes t pico 85 S loBM80 2 y BM82 2...

Страница 87: ...72 188 Opcionales Conjunto de conductor con fusible FPK8 6111 218 Estuche port til con cremallera 6420 132 Base de teleenv o DLB 6420 602 Sonda de prueba del interruptor SP6F 6220 836 Transductor de c...

Страница 88: ...ara realizar trabajos de reparaci n de la mayor a de los instrumentos Megger utilizando aut nticas piezas de repuesto Megger Consulte con su Agente Distribuidor con referencia a las pi ezas de repuest...

Страница 89: ...fe Road Dover Kent CT17 9EN ENGLAND T 44 0 1 304 502101 F 44 0 1 304 207342 Megger 4271 Bronze Way Dallas TX 75237 1019 USA T 1 800 723 2861 T 1 214 333 3201 F 1 214 331 7399 Megger Z A Du Buisson de...

Отзывы: