PERFORMANCE PARAMETERS
Model
Rating Power
Heating mode
Power
Fan mode
Power
Max Water
Injection Rate
NFS-20
220-240V~ 50/60Hz
2000W
75W
6.5L
FUNCTIONS
●
Heat
: Heated by PTC heating unit, which has highly efficient conversion between electricity
and heat, and rapid heating.
●
Cooling:
this is achieved by a honeycomb filter design that provides maximum surface area and
optimizes cooling performance. Air is forced to come in contact with evaporating water which
provides maximum cooling effect. This is a powerful motor which is designed to deliver
maximum airflow with minimum noise.
●
Anion:
Air purification through Ionization of charged particles
.
●
Adjustable speed: the unit has
three speeds for Cooling and 2 speeds for heating.
●
Modes: Normal, Natural and Sleep.
In normal mode the unit delivers constant air at a selected
speed. Natural Mode provides variable airflow similar to that blows in forests. Sleep mode is
working with soft wind.
●
SWING : This provides horizontal movement of air
, to cover wide area for heating or cooling
by movement of front louver vents.
The air direction can also be adjusted vertically and
downwards by adjusting internal louver vents mechanically by hand.
●
Remote control:
6 meters range
remote control. Requires 2 X AAA
ASSEMBLING AND PREPARATION
1.
Place the appliance on a flat surface, with the help of small spanner (provided) take out the
assemble the castors at the base in the four holes provided. Castors come with self tapping screw
and will screw into the holes with a small amount of force with spanner.
Note: The back castors come with brake, and the front ones do not have brakes. (map 1)
2.
Water: Pull out half of the water tank at the back, add approx. 4 litres of water.(map 2)
Attention:
a.
Pay attention to the level of water tank when adding water.(map 3)
b.
The level of water tank should not over “MAX” scale at any time, and total level of water
tank should not below “MIN” scale. Minimum level takes approx. 3 litre and maximum up
to 6 litres of water.
c.
You can put Ice cubes or pre chilled ice bottles directly into the water tank if you want to
cooler air. However the total level of water tank should not be over “MAX” scale.