PUTTING THE GENERATOR INTO OPERATION  

 

 

  

Please  follow  strictly  the  described  steps.  It  helps  to  prevent  damage  the 
generator, other equipment, and personnel injury. 

  

Step 1. 

Unpack  the  generator  and  check  the  presence  into  the  package  of  the  following 
items: 

-

 

NPG-20/3500 (NPG-20/3500N) generator; 

-

 

power supply cable; 

-

 

output 50 Ohm coaxial cable. 

 

Step 2. 

Set up the generator. Ground it obligatory by connecting ground cable to terminal 
on  the  rear  panel  (12)  and/or  use  three-terminal  power  supply  outlet  with 
grounding contact. 
 

Step 3. 

Check the output coaxial female connector on the front panel of the generator (2) 
and co-pair male connector on the cable. Both connectors should be clean and dry, 
free  from  dust,  dirt,  and  any  obstacles.  Clean the  connectors  with alcohol  and/or 
cotton bud if necessary, put a drop of silicone oil onto the Teflon insulating parts. 
Attach the cable connector to the generator front panel connector (2). The tight and 
firm  contact  of  the  connectors  is  very  important  for  the  normal  operation  of  the 
generator.  Even  a  small  air  gap  between  the  connectors  may  result  in  arcing, 
destroying the generator and the cable. 
To obtain good and tight contact the following procedure is recommended: 

1.

 

Align both connectors. 

2.

 

Hold  the  generator  by  one  hand  to  prevent  moving  and  press  the  cable 

connector by another hand toward the generator connector. 

3.

 

Screw the cable connector nut by hand, usually one or two turns. Do not 

rotate the cable connector body. 

4.

 

Press the cable connector toward the generator connector again. 

5.

 

Once more screw the cable connector nut one or two turns. 

6.

 

Repeat steps 4 and 5 up to tight contact. Finally screw the cable connector 

nut firmly by hand.  

It is recommended to check whether the tight contact obtained or not after the first 
test  operation  of  the  generator.  Unscrew  the  cable  connector;  there  should  be  no 
ozone  or  burnt  smell  from  the  cable  connector,  even  a little,  or  any  burnt traces. 
Please  do  not  connect  and  disconnect the high  voltage  connectors many  times  to 
prevent the contacts from wearing.  

NPG-20/3500 and NPG-20/3500N   User manual                                                    7

 

Содержание NPG-20/3500

Страница 1: ...NANOSECOND PULSE GENERATOR NPG 20 3500 and NPG 20 3500N USER MANUAL 2021 Megaimpulse Ltd v 1 0...

Страница 2: ...OR ERROR IN THIS MANUAL OR PRODUCT SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR INFORMATION ONLY AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE AND SHOULD NOT BE CO...

Страница 3: ...ond pulse generator 3 Description 4 Technical specification 5 Front and rear panels view 6 Putting the generator into operation 7 Triggering of the generator 9 Overheat mode 10 Output pulse monitoring...

Страница 4: ...nerator to or from the system ensure that the power supply ON OFF switch is switched off and the power supply cable is unplugged before the output cable is connected or disconnected Please connect or...

Страница 5: ...500 positive polarity or NPG 20 3500 negative polarity nanosecond pulse generator hereinafter generator Power supply cable High voltage output coaxial cable User manual Fig 1 General view of NPG 20 35...

Страница 6: ...itude knob is in max position The generator is designed for operation with 50 Ohm impedance load only for example properly made antenna In spite of the generator has protection from overheating and da...

Страница 7: ...tion rate from 1 Hz up to 3 5 kHz Single pulse mode yes in external triggering mode Triggering internal or external External triggering BNC input connector 2 5V 15V amplitude 50 s 200 s pulse width In...

Страница 8: ...ctor 3 power supply connector and fuse holder 4 HV ON HV OFF high voltage on off switch 5 EXT INT external internal triggering switch 6 BNC SYNC IN connector 7 OVERHEAT LED 8 AMPLITUDE regulation knob...

Страница 9: ...t of the connectors is very important for the normal operation of the generator Even a small air gap between the connectors may result in arcing destroying the generator and the cable To obtain good a...

Страница 10: ...er outlet Switch on the generator by the power switch 1 on the rear panel The internal fans 11 of the generator should start to rotate Step 6 Switch on the high voltage by HV ON HV OFF switch 4 The ou...

Страница 11: ...ypical jitter RMS is about 1 ns The internal red lamp in HV ON HV OFF switch 4 lights on and indicates the generator triggering The maximum allowable pulse repetition rate in this mode is limited by F...

Страница 12: ...h 4 and allow fans to cool the generator for several minutes OVERHEAT LED 7 lights off after the cooling and the generator is ready for operation again Unfortunately the matching with the load usually...

Страница 13: ...ng interference Therefore one can see the noise on the oscillograms at the moment of the output pulse generation The measured in Fig 3 delay between external triggering pulse and the output pulse is 1...

Страница 14: ...rminal power supply connector Please use a flat screwdriver or another suitable tool to remove the fuse holder see Fig 4 Fig 4 Removing of the fuse holder by a flat screwdriver There are two fuses in...

Страница 15: ...arranty period and warranty condition The generator has warranty seals on the front and rear panels see Fig 6 Removing of the warranty seals terminates the warranty Fig 6 Warranty seals on the front a...

Отзывы: