background image

 

megascan M1

 User Manual Rev. 1.0 

Updated on 28th

 

August, 2009     

Technical Contacts and Enquiry: [email protected] 

 

 

 

 

Website: www.scanmega.com 

                            (This user manual / product specification is subjected to be changed without prior notice)                          P.

1

 

 

 

 

 

 

 

 

 

 

 

megascan M1 User Manual 

Rev. 1.0 

Model: megascan M1 

 

 

 

 

                       

                 

Содержание megascan M1

Страница 1: ...d on 28th August 2009 Technical Contacts and Enquiry sales scanmega com Website www scanmega com This user manual product specification is subjected to be changed without prior notice P 1 megascan M1...

Страница 2: ...ct Features 8 1 6 Specification 9 Chapter 2 Installation of megascan M1 10 2 1 Power up megascan M1 10 2 2 Environmental Requirements 10 2 3 Start up Procedures 11 2 4 Caution 11 2 5 Professional Inst...

Страница 3: ...15 certification It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States The use of the system in any other combinat...

Страница 4: ...processing speed and ample memory is an UHF RFID reader which includes powerful RFID reader with 17 RFID antenna ports which operates in 860MHz to 930MHz UHF band and is compliance with ISO 18000 6C...

Страница 5: ...notice P 5 1 2 Ports Description The megascan M1 has several types of input output port Items Name Description 1 Ethernet Port RJ 45 10BaseTx 100BaseTx port that connects the reader to your Ethernet n...

Страница 6: ...e P 6 1 3 Indicators LEDs in megascan M1 The megascan M1 has different LEDs to indicate the reader status Name Label Description LAN Status 10BaseTx 10M Turn ON when 10Mbps network detected LAN Status...

Страница 7: ...and Enquiry sales scanmega com Website www scanmega com This user manual product specification is subjected to be changed without prior notice P 7 1 4 Antenna for megascan M1 There is no antenna shipp...

Страница 8: ...tivity Consistently supports read ranges up to 30 feet Dense Reader Mode DRM Capability Power over Ethernet PoE connectivity Low power consumption Adjustable output Tx power levels over 5 to 30dBm ran...

Страница 9: ...MHz ETSI 865 868 MHz NCC 922 928 MHz SRRC 920 925 MHz RF Output Power Adjustable from 5 to 30dBm in 1 dB steps Supply Voltage Power over Ethernet PoE IEEE standard 802 3af compliant Power Consumption...

Страница 10: ...connect with Cat 5 and higher infrastructure cable Antenna port is standard SMA Jack female the RF cable antenna connector should be standard SMA Plug male megascan M1 operates at UHF frequency band r...

Страница 11: ...s connected an UHF antenna before turn on the RF power for testing Caution Each port must have either an antenna or a terminator connected Do not apply power to the megascan M1 unless an antenna or te...

Страница 12: ...rict accordance with the manufacturer s instructions as described in the user documentation provided Installation of these products in the end use must conform to local regulations and codes Products...

Страница 13: ...its Warnings Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment The equipment has been tested...

Страница 14: ...or authorization to use this device prior to turning on the equipment Modifications The FCC requires the user to be notified that any changes or modifications to this device that are not expressly app...

Страница 15: ...cation with megascan M1 Megabyte Ltd megascan M1 is an intelligent reader and compliance with EPC global C1G2 ISO 18000 6C Users can develop own UHF RFID application on this platform 3 1 1 Delivering...

Страница 16: ...turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation...

Страница 17: ...tain compliance with the power density limit The minimum required cable length is 1 5m to be used with this device The following formula was used to calculate the Power Density S Where S Power Density...

Страница 18: ...Marking The CE Mark is a conformity marking consisting of the letters CE The CE Mark applies to products regulated by certain European health safety and environmental protection legislation The CE Mar...

Страница 19: ...tion with the furnishing performance or use of this material This document contains proprietary information which is protected by international patent applications and copyright All rights reserved No...

Страница 20: ...bserve this User Manual and the instructions accompanying the Products or any alterations maintenance or repair to the Products by any person other than Megabyte Ltd use of non Megabyte Ltd parts acce...

Страница 21: ...tacts and Enquiry sales scanmega com Website www scanmega com This user manual product specification is subjected to be changed without prior notice P 21 Chapter 7 Support Technical support sales enqu...

Отзывы: