1)  Locate  pump  as  close  to  pool  as  possible,  preferably  in  a  dry,  well  ventilated 

area away from direct sunlight. Pump Mount must:

-   

Be  on  solid,  level,  rigid  and  vibration  free  surface.  ecure  pump  to  base  with 

screws or bolts to further reduce vibration and stress on pipe or hose joints

-  

Allow pump suction inlet height t be as close to water level as possible.

-  

Allow use of short, direct suction pipe (To reduce friction loss.)

2) Fixed he pump by screws onto the platform.
3)  Connect  the  suction  and  discharge  pipe  to  the  outlet  and  inlet  of  the 

swimming pool.

4) The installation instructions shall provide information on requirements specified 

for  the  electrical  installation  and  shall  include  reference  to  national  wiring 
rules.

5)  The  installation  instructions  shall  state  the  substance  of  the  following:  -  the 

maximum total head, in metres (Hmax:20m)

6)  the  pump  is  to  be  supplied  through  a  residual  current  device  (RCD)  having  a 

rated residual operating current not exceeding 30 mA.

    This  appliance  is  not  intended  for  use  by  persons  (including  children)  with 

reduced  physical,  sensory  or  mental  capabilities,  or  lack  of  experience  and 
knowledge, unless they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety.Children should be 
supervised to ensure that they do not play with the appliance.

Hazardous suction.

Can trap hair or body 

part, causing severe 

injury or death.Do not 

block suction.

3

Correct Disposal of this product

This marking indicates that this product should 
not be disposed with other household wastes 
throughout  the  EU.  To  prevent  possible  harm 
to  the  environment  or  human  health  from 
uncontrolled  waste  disposal,  recycle  it  resp 
onsibly  to  promote  the  sustainable  reuse  of 
material  resources.  To  return  your  used 
device,  please  use  the  return  and  collection 
systems  or  contact  the  retailer  where  the 
product  was  purchased.  They  can  take  this 
product for environmental safe recycling.

Содержание 88029807

Страница 1: ...SPV Pump Installation Operating Instructions MEPU18070642...

Страница 2: ...nstallation 4 User s Guide 4 5 Menu Structure 6 7 Programming 8 Fault Treatment 9 Routine Maintenance 13 Service Repair Parts 13 Trouble Shooting 14 Replacement Parts 15 Dimension 16 Product Informati...

Страница 3: ...of the following the maximum total head in metres Hmax 20m 6 the pump is to be supplied through a residual current device RCD having a rated residual operating current not exceeding 30 mA This applian...

Страница 4: ...oceeding RELEASE ALL PRESSURE from pump and piping system NEVER tighten or loosen screws while pump is operation Do not block pump suction 1 2 Priming Pump In a flooded suction system water source hig...

Страница 5: ...reset Speed 1 Quick Setting Preset Speed 2 Quick Setting Preset Speed 3 Quick Setting 2 2 2 Indication Light Reference S1 S2 S3 Running Light Operation Light Flashing Preset Speed 1 Enable 1 0 0 X 0 P...

Страница 6: ...Short press Speed 3 Cancell E g SP 1000 Unit RPM E g P 0 Unit Watt W E g CI 0 00 E g 1S 1500 800 3400RPM E g 1O 00 00 00 00 23 59 E g 1F 0 00 00 00 23 59 E g 1E Off On Off E g PL 2 1 20 mins E g PS 2...

Страница 7: ...When in the Time Dislay page Enter Time Setting When in other pages Enter Setting Interface Enter Monitoring Interface N A N A Short press Start Stop Start Stop Start Stop N A Auto Recovery Long press...

Страница 8: ...Self Priming setting has 3 parameters Self Priming Time Self Priming Speed Enable Disable 2 Self Priming function will be activated if the function is enable the running speed is lower than the Self...

Страница 9: ...e Over power of the power supply Power supply voltage exceeds controller setting UV The main electric current is too low Voltage Under Power supply disconnected driver discharging Supply voltage fluct...

Страница 10: ...oring Interface Diagram 6 4 Power consumption display page Diagram 6 5 Time display page Short press Speed1 to Speed3 to switch to the 3 preset speeds the corresponding indication light will on as dia...

Страница 11: ...Speed Schedule 2 Time On Schedule 2 Time Off Schedule 2 Enable Disable Schedule 3 Speed Self Priming Time Self Priming Speed Self Priming Enable Disable Auto Recovery pages As diagram 6 12 6 23 Diagra...

Страница 12: ...y automatically If two errors happened in less than 60 seconds interval the auto recovery time will increase once If the auto recovery increase to 3 times the system will direct to the Error menu and...

Страница 13: ...discharge and release all pressure from system before proceeding 2 Unscrew trap lid turn counterclockwise 3 Remove strainer basket and clean Be sure all holes in basket are clear flush basket with wat...

Страница 14: ...W PUMP CAPACITY 1 Valve in suction or discharge line partly closed 2 Suction or discharge line partly plugged 3 Suction or discharge line too small 4 Plugged basket in skimmer or hair and lint straine...

Страница 15: ...al Seal 1 13 02010246 O Ring for Flange 1 14 01021145 Flange 1 15 89020720 M8 35 Screw with Washer for Motor 4 16 03011075 M8 30 Screw 4 17 04020140 SPV150 Motor 1 18 01112082 Base 1 18 02010211 Arch...

Страница 16: ...81 300 8 46 215 7 68 195 22 37 568 20 9 33 237 10 60 269 6 06 154 8 62 219 5 00 126 90 5 25 133 43 4 41 112 12 Product Information Code Mode Code Connection lnput Power Horsepower RPM 88029807 SPV150...

Отзывы: