background image

Caution!   

1.   

Do not connect fixture to a dimmer system. 

2.   

This unit has Auto switching power supply.  It will respond to 110V or 220V automatically 

3.   

This unit must be earthed. (electronically grounded)  

The occupation of the connection-cable is as follows: 

This fixture is equipped with an electronic power supply that will let the unit operate from 100V to 240V from 50Hz to 60Hz 

The fixture is equipped with Neutrik NC3FXX-HD and NC3MXX-HD IP 67 3 pin XLR Sockets for DMX input and output.  

The sockets are wired in parallel.  Only use a shielded twisted pair cable designed for RS-485 and 3 pin XLR plugs and 

connectors in order to connect the controller with the fixture or the fixture with another. 

Caution! 

At the last fixture the DMX signal needs to be terminated with a terminator. Solder a 120 Ohm re-

sistor between the (-) and the (+) signal into a 3 pin XLR plug and plug it in to the last fixture on 

the signal run.  Pre-manufactured terminator plugs are available for  

purchase from your Mega-Lite dealer (P-DMX-T). 

Cable (USA) 

Cable (EU) 

Pin 

110V 

Black 

Brown 

White 

DMX-512 Connection 

Green 

Light Blue 

Yellow/Green 

Live 

Neutral 

Ground 

 

220V 

 

DMX—input 

DMX—output 

1.  Shield 

2.  Signal (-) 

3.  Signal (+) 

Main Power Connection 

Содержание Indi PAR RW300

Страница 1: ...ER MANUAL Table of Contents Safety Information 3 Specifications 4 Main Power Connection 5 DMX 512 Connection 5 Main Control Menu 6 DMX Profile 8 Rigging the Fixture 9 Cleaning Maintenance 9 Parts List...

Страница 2: ......

Страница 3: ...y secured 6 Maximum surface operating temperature 140 Protection Against Electrical Shock 1 Disconnect power before servicing 2 For connection to main power supply proceed to page 5 3 This unit must b...

Страница 4: ...k True Power NAC3FX W Connections to Nema 5 15 adapter included Weather Covers for unused connections included Thermal Maximum ambient temperature 104 Maximum surface temperature 140 Fastening System...

Страница 5: ...parallel Only use a shielded twisted pair cable designed for RS 485 and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or the fixture with another Caution At the l...

Страница 6: ...ve a dimming time to 3 that will have the longest dimming time press Mode to confirm your setting Auto This function will give you access to the Preprogramed Chases Press and hold Mode Use the or to s...

Страница 7: ...ess DMX on or off Press the Function button from your Mega Air wireless transmitter Set the display on your fixture to the DMX screen and set the DMX start channel to the desired channel note If fixtu...

Страница 8: ...255 6Ch DMX Chanel Function Description Value 1 Dimmer Dimmer Off to Full 0 255 2 LED Color Red LED intensity 0 255 3 LED Color Green LED Intensity 0 255 4 LED Color Blue LED Intensity 0 255 5 Strobe...

Страница 9: ...trained professional only Should you have further questions please contact your dealer Parts List 7300 MPCB Main PCB card 7300 PS Power Supply 7300 DIS Display 7300 LEDMOD LED Module 7300 LED Replacem...

Страница 10: ...with the freight prepaid by MSI via the most economical means of shipment Repair or replacement as provided for under this warranty is the exclusive remedy of the consumer MEGA SYSTEMS INC makes no w...

Отзывы: