8
Main Control Menu
The control board on the fixture base is your interface to access and control
all the functions on the unit. Its digital display gives you a code view of the
options and functions including errors and diagnostics. The following will ex-
plain each function and its options. Press Mode button to scroll through the
different options.
MODE
MO
DE
ENTER
EN
TE
R
DOWN
DO
WN
UP
UP
DMX
DMX Address
Use the
up/down
keys to select the required DMX channel. Press
Enter
to confirm or
Mode
to exit and return to main menu.
The display will flash if there is no DMX signal been received from the console. The Axis 500 uses 16 or 14 DMX channels
DMX Address
Programme
Pan Reverse
Tilt Reverse
Demo Mode
Unit Reset
Display
0
-
512
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Programme Version
No function this will just show you what version of program you have.
Reverse Pan
This function allows you to invert the Pan direction. Use the
up/down
keys to select,
Y
to invert pan and
N
not to invert the pan.
Press
Enter
to confirm or
Mode
exit and return to the mail menu.
Reverse Tilt
This function allows you to invert the Tilt direction. Use the
up/down
keys to select,
Y
to invert tilt and
N
not to invert the tilt.
Press
Enter
to confirm or
Mode
exit and return to the mail menu.
Demo Mode
This function allows you to turn on the demo mode operation. Use the
up/down
keys to select,
Y
to turn demo mode on and
N
not to turn demo mode on. Press
Enter
to confirm or
Mode
exit and return to the mail menu.
This function allows you to reset the fixture. Use the
up/down
keys to select,
Y
to reset the fixture and
N
not to reset the fixture.
Press
Enter
to confirm or
Mode
exit and return to the mail menu.
Unit Reset
Display reverse
This function allows you to invert the display direction. Use the
up/down
keys to select,
Y
to invert display and
N
not to invert the
display. Press
Enter
to confirm or
Mode
exit and return to the mail menu.