Mega Lite ARFlood Скачать руководство пользователя страница 5

Main Power Connection 

Caution!   

1.   

Do not connect fixture to a dimmer system. 

2.   

This unit has Auto switching power supply.  It will respond to 110V or 220V automatically 

3.   

This unit must be earthed. (electronically grounded)  

4. 

Replace fuse only with the specified type and rating. 

The occupation of the connection-cable is as follows: 

DMX-512 Connection 

110V  Connection 

The fixture is equipped with 3 pin XLR Sockets for DMX input and output.  The sockets are wired in parallel.  Only use a shielded 
twisted pair cable designed for RS-485 and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or 
the fixture with another. 

DMX—input 

DMX—output 

1.  Shield 

2.  Signal (-) 

3.  Signal (+) 

Caution! 

At the last fixture the DMX signal needs to be terminated with a terminator. Solder a 120 
Ohm resistor between the (-) and the (+) signal into a 3 pin XLR plug and plug it in to the 
last fixture on the signal run.  Pre-manufactured terminator plugs are available for  
purchase from your Mega-Lite dealer (HOS-DMXT). 

Cable (USA) 

Cable (EU) 

Pin 

Connection 

Black 

Brown 

White 

Green 

Light Blue 

Yellow/Green 

Live 

Neutral 

Ground 

 

Cable (USA) 

Cable (EU) 

Pin 

Connection 

Black 

Brown 

White 

Green 

Light Blue 

Yellow/Green 

Live 

Live 

 

 

220V Connection 

Содержание ARFlood

Страница 1: ...ER MANUAL Table of Contents Safety Information 3 Specifications 4 Main Power Connection 5 DMX 512 Connection 5 Rigging the Fixture 6 Main Control Menu 6 DMX Profile 6 Cleaning Maintenance 7 Parts List...

Страница 2: ......

Страница 3: ...to a heat source 5 Make sure cable are properly secured away from unit movement Protection Against Fire 1 Disconnect power before servicing 2 For connection to main power supply proceed to page 5 3 Th...

Страница 4: ...Rating IP 65 Display Digital display Fastening System Mounting Yoke Material Die Cast aluminum Electrical Specifications LED Quantity 48 Red 16 Green 16 Blue 16 LED Watts 1 watt LED Manufacture Bridge...

Страница 5: ...e designed for RS 485 and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or the fixture with another DMX input DMX output 1 Shield 2 Signal 3 Signal Caution At the...

Страница 6: ...secondary safety attachment The installation location of the projector has got to be built in the way that it can hold 10 times the weight for 1 hour with out any harming Installation should be check...

Страница 7: ...killed installer and any safety problems have to be removed Disconnect from mains before starting maintenance operation Caution Danger to life We recommend a frequent cleaning of the device Please use...

Страница 8: ...ed problem or malfunction Ship returned Prod uct units or parts to 5711 Kenwick St San Antonio TX 78254 USA Note Freight Damage Claims are invalid for fixtures shipped in non factory boxes and packing...

Отзывы: