Installation and Notice

The MEFU Laminator should be assembled and used in a clean room with a

normal room temperature and normal humidity levels. The work place

should be dry and ventilated. Do not use this machine near water source or

wet ground. This minimize the occurrence of static electricity. In the

meanwhile, do not close to combustible and explosive goods.

Delivery inspection

When the machine is delivered, the following units are included:

·

MEFU laminator

·

Manual

·

Accessories

Connections

Voltage: AC220/240V 50-60HZ

Positioning

The MEFU Laminator should be placed in a dry and ventilated situation.

Electrical connectors may only be connected to

socked to sockets with the correct voltage. All

other operations may only be performed by

authorized staff.

Before use

Check the chains and gears (at a regular time), clean and lubricate.

Using

The roller is hot during working, please do not touch it,in case of scalded or bruised.

After use

Place the roller in the idle position, raised 5 mm above the working table.

Clean the roller at a regular time, do not use water to clean the machine in case of short

circuit, electric shock or rust.

Use 80% alcohol, detergent or eraser to clean the rollers after lamination, which can

lengthen the rollers' life.

1.The temperature of the roller should under 40

and stop heating.

2.

Do not focus on one point.

3.

Clean the residuum in time, otherwise it will affect the yields.

Assembly with the steps performed by technician

authorized

8

9

Содержание MF1600-M1

Страница 1: ...Laminate Your Value www mefuchina com Heat Assist cold laminator MF1600 M1 1...

Страница 2: ...ed as an inexpensive option for post printers Heat assist can absolutely avoid air bubbles and snow points for cold weather Its simple design makes it extremely easy to use and provides quality lamina...

Страница 3: ...ing symbols in this manual roller Hot lamination indicator for top roller Cold lamination indicator for top roller Prepare lamination indicator for top roller SET button Temp Set up Temp Set down Forw...

Страница 4: ...re operation Maintenance Do not use water to clean the machine in case of short circuit electric shock or rust In order not to hurt the rollers please do not put any hard stuff on the machine Check th...

Страница 5: ...l connectors may only be connected to socked to sockets with the correct voltage All other operations may only be performed by authorized staff Before use Check the chains and gears at a regular time...

Страница 6: ...aphic and paper tube to the the lower rolls feeding roll and finish product roll and measure them straightly with scale on the rolls 1 Install the foot switch and plug in the power 4 Peel off the line...

Страница 7: ...er with recommended temperature of 40 50 9 Press the Continue switch to laminate 5 Feed the graphic slightly into the rollers 6 Put down the roll to keep the feeding graphic steady 7 Lift down the rol...

Страница 8: ...e film Maintenance Every day Make sure that the machine is not held any hard stuff and the roller is not damaged check the buttons on the machine Once a week clean the machine Once a month clean and l...

Страница 9: ...this helps please contact a technician Control panel dead fault 1 Check power supply or emergency button 2 If the fuse is burn down just replace The roller can not run 1 Regulate the fraction of the...