4.5 Cleaning and Washing
Disconnect the plug from the wall socket. The scaling/scarping/shaving end of the machine may be washed in warm water us-
ing detergent and a dish brush. The rubber and the machine itself may be wiped clean using a damp cloth. DO NOT use running
water to clean the motor, DO NOT wet the switch and DO NOT use a pressure hose.
4.6 Maintenance
The machine does not require maintenance, except for daily cleaning. The service life of the casing wire can be increased by
oiling. When necessary the casing and flexible wire must be replaced. DO NOT wash the machine with a shower.
5. Fault Finding
6. Exploded Drawing Diagram
Fault
Cause
Suggestion
The machine does not start
(a) The plug is not attached to the sock-
et
(b) The switch is broken
(c) The electrical cord is broken
Contact an authorized electrician or the
manufacturer.
The knife end does not rotate
The rubber tube is broken
Replace the rubber tube
The rubber tube is fractured
The rubber tube is broken
Replace the rubber tube
The scales/hair will not come off
The knife end is blunt
OR
Incorrect or insufficient scalding
(a) Use a fine file to sharpen the teeth of
the knife