Ionising bars will need periodic wiping to clean grey deposits from the surface
of the bar. A cloth moistened with a small amount of IPA or methylated spirits is
recommended.
Let dry for a minute before turning back on.
After prolonged use, perhaps after several years, the emitter pins may become worn
and require replacement. Bags of replacement pins are available from Meech and are
supplied with a special insertion tool.
Important!
1. When replacing the emitters, only use the Meech Insertion Tool. No other tools
should be used.
2. The emitters should only be tightened finger-tight. Over-tightening the emitters will
stress them unnecessarily and may cause failure.