Troubleshooting
Solid Green LED
Meaning
In normal operation the LED on the bar will
illuminate Green. This indicates that the bar
is operating correctly with good ionisation
performance.
No LED
Meaning
No power to bar
Action
Check 24V Power Supply over pins 1 and 3.
(Brown and Blue wires)
Flashing Green LED Meaning
BarMaster remote programmer is connected.
Action
After programming, reconnect directly to the
power supply to resume normal operation.
Flashing Red LED
Likely cause Contamination causing a drop in performance
Action
Switch off power supply. Turn the power on
and check for green solid LED
Solid Red LED
Likely Cause Abnormal output current detected
Action
Check installation for metallic objects on the
emitter pins.
Should the solid red LED persist, contact your
Meech distributor