background image

 

Operating Manual

Hyperion 906 

High Voltage Power Supply

v1.13A

Содержание Hyperion 906

Страница 1: ...Operating Manual Hyperion 906 High Voltage Power Supply v1 13A...

Страница 2: ......

Страница 3: ...2017 Contents Introduction 3 Unpacking And Inspection 4 Contents 4 Standard Options Input Voltage and Connection 5 Installation 5 Ionising Equipment Connection 5 Fault finding and diagnostic check 9...

Страница 4: ......

Страница 5: ...djustable output of 4 7kV AC The 906 provides AC power for any Meech AC Ioniser The 24V DC input voltage suits modern machinery and means that they operate independently of local mains voltage and fre...

Страница 6: ...ge is evident do not destroy the carton or packing material and immediately notify the carrier of a possible damage claim Shipping claims must be made by the consignee to the delivering carrier Conten...

Страница 7: ...mounting it is important that the power unit is mounted in such a way so oil or moisture from other sources cannot contaminate the power unit Failure to the unit through contamination will invalidate...

Страница 8: ...e swivel connector of the appliance Push the connector through a port in the Hyperion power supply Re fit the lock washer and nut to secure the appliance cable Make sure the nut is fully tightened Rem...

Страница 9: ...stage 1 make sure all of the nuts are fully tightened before the lid is attached 24V 4 pole extension cables are available from Meech in 1 3 and 8 meter lengths Ensure the 24V supply is off before con...

Страница 10: ...F OK Green LED 24V 0V OK Green LED 0V 0V Dirty Faulty Red LED 0V 0V Dirty Faulty Red LED 24V 0V External Relay Wiring 10k Pull up 24VDC 0V Imax 20mA NO COM NC Relay Power Normally Open Output Matrix N...

Страница 11: ...angle the 906 has twin LED indicators Their colour and state show whether the system is operating correctly or whether it needs attention The meaning of the colours and states is as follows Colour St...

Страница 12: ...Weight 2 2kg Input Voltage 24V DC N B Supply must be grounded Input Current 200mA 2A Load Dependant Output Voltage 4000 7000V AC Output Frequency 67Hz Connection Murr 4pin M8 Earth terminal Settings C...

Страница 13: ...m the bar Failure to do so will not damage the equipment but may result in a small shock caused by the stored energy in the bar Attach the cable on the BarMaster to the M8 connector on the power unit...

Страница 14: ...he parameter to be adjusted To scroll through the menu use the up down function To adjust Voltage or Frequency use left and right function Please note the OK button in the centre of the toggle is redu...

Страница 15: ...Lower frequencies can assist long range use Higher frequencies give better results at short range Output Voltage 4kV 7kV Using a BarMaster programmer it is possible to set the output voltage of the 9...

Страница 16: ...iginal purchaser against defects in the material and workmanship for two years after shipment Should any malfunction occur please return the power supply directly to Meech Static Eliminators or your l...

Страница 17: ...R USED FOR MANUFACTURE OR OTHERWISE DISCLOSED WITHOUT THE PRIOR WRITTEN CONSENT OF MEECH INTERNATIONAL MATERIAL FINISH TOLERANCE UNLESS OTHERWISE SPECIFIED Machined Work Metric 0 1mm Unmachined Fabric...

Страница 18: ...Conformity for this product exists in respect of the Low Voltage Directive 72 23 EEC LVD Electromagnetic Compatibility Directive 89 336 EEC EMCD Health and Safety Emission of Ozone Considerably below...

Страница 19: ......

Страница 20: ...232 4210 Fax 1 330 564 2005 email info meech com Meech Shavotech 29 2 Kharadi Off Pune Nagar Road On Old Kharadi Mundhwa Road Pune 411014 Maharashtra India Tel 91 0 703 093 8211 91 0 741 000 4817 Fax...

Отзывы: