5. Using a high voltage probe and meter measure the voltage on the pins of the
ionising bar. This voltage should be approximately 4.5 kV.
6. If the voltage is below 4.0 kV then the bar should be returned to Meech for service
and/or repair.
7. If no meter and probe is available, then a fast and simple test can be
undertaken by shorting a pin of the bar to earth.
Attach a short length of insulated wire to either fixing stud on the bar.
13