ENGLISH
33
Replacing and adjusting the blades
WARNING
Turn off the machine, unplug the power cord and wait until all moving parts have stopped
completely before replacing or adjusting the blades.
Dismantling
1.
Remove the guard by loosening the screws
(U) (see picture).
2.
Loosen the locking plate (B) and blade (C) by
turning the clamping screws (A) clockwise.
The blades are spring-loaded (D) and can be
removed when the holder is removed.
3.
Remove the blade and locking plate.
Assembly
1.
Place the blade against the locking plate, in the correct
position relative to the pins (F) (see picture).
2.
Insert the blade and locking plate together in the slot and
lock in position by turning the clamping screws anti-
clockwise. Ensure that the blades face in the right
direction (see picture).
3.
Adjust the blade projection to 1.5 mm by placing the
template (E) of the blade holder. Loosen, if necessary,
the clamping screws to move the blade to the correct
position. When the blade is positioned correctly, hold it
firmly in place and tighten the clamping screws (A).
WARNING
Check that all 6 screws are tightened. Turn the
blade holder by hand to check that it rotates easily and
smoothly.
Handle the blades with care - risk of personal injury and/or