ENGLISH
26
1.
Casing
2.
Power switch On/Off
3.
Clip for cover
4.
Carrying handle
5.
Power cord
6.
Suction hose
7.
Suction/blower nozzle
8.
Flat suction nozzle
9.
Drill hole suction nozzle
10.
Cover for dust bag
11.
Dust bag
12.
Dust filter
13.
Clip
14.
Nozzle
15.
Grille
16.
Vacuum connection
17.
Blower connection
OPERATION
Fitting/replacing dust bag, fig. 2-3
1.
Open both clips (3) and fold back the cover.
2.
Open the cover for the dust bag (10), press the clip (12) on the dust bag, and press it over the
suction nozzle.
3.
Close the cover again until it clicks into place. When emptying a full dust bag, clean the area round
the dust bag with a damp cloth or brush before replacing it again.
4.
Place the connecting cord in the slot (A) on the front.
5.
Close the casing and lock with the two clips.
Vacuum function, fig. 4-7
1.
When using the vacuum function
– always fit a dust bag.
2.
The connecting nozzle (14) fits into the side of the dust bag (16).
3.
Put the grille and filter on the opposite side.
4.
Make sure that both parts click into place. Insert the suction hose (6) with the lug in the connecting
nozzle (14) and lock in place by twisting it a little.
5.
Put the jet nozzle on the suction hose, plug in the mains plug, and press the button.
Use, (fig. 4-7
1.
The machine can be used as a blower in a few simple steps.
2.
Remove the connecting nozzle (14) from the vacuum side and put it on the opposite side (17).
3.
Put the grille and filter on the vacuum side.
4.
Connect the suction hose and put on the blower nozzle (7).
5.
Closing the hole on the jet nozzle increases the pressure.
6.
Do not point the air flow at persons or animals.
Using the drill hole nozzle, fig.8
1.
Put the drill hole nozzle (9) on the suction hose.
2.
Switch on the vacuum device and place the drill hole nozzle in the drill hole. The nozzle sticks by
means of the vacuum to smooth surfaces.
Using the inflation nozzle, fig. 9-10
1.
The blower nozzle (7) can be used to deflate or inflate suitable objects.
2.
Put the vacuum device in blower mode.
3.
Put the blower nozzle on the suction hose.
4.
Switch on the vacuum device.
5.
You can adjust the air flow by blocking a drill hole (a) on the nozzle.
Содержание 230-007
Страница 3: ...3 Using the inflation nozzle fig 9 10 26 MAINTENANCE 27 ...
Страница 6: ...SVENSKA 6 ILLUSTRATIONER ...
Страница 7: ...SVENSKA 7 ...
Страница 12: ...NORSK 12 ILLUSTRASJONER ...
Страница 13: ...NORSK 13 ...
Страница 18: ...POLSKI 18 RYSUNKI ...
Страница 19: ...POLSKI 19 ...
Страница 24: ...ENGLISH 24 DIAGRAMS ...
Страница 25: ...ENGLISH 25 ...
Страница 28: ......