background image

13

 

U Manual 

 UVP-I-MULVAC-1 

Effective 12-09-16

 

 

LIMITED WARRANTY

 

 

MedRx, Inc warrants this product to be free from defects in material and 

workmanship for one year from the time of purchase. If this system fails to perform 

as specified during this period, the purchaser is responsible for calling MedRx at 

(888) 392-1234 or (727) 584-9600. The company's representative will advise the 

owner to either return specific components or the entire system to:

 

 

MedRx, Inc.

 

1200 Starkey Road #105 

Largo, FL 33771 USA

 

 

MedRx will repair or replace any defective devices, fully test the system and/or 

components and ship the system promptly back to the owner. There is no cost for the 

repair or return shipping, provided the system is one year old or less and has not 

been misused, abused or damaged. Such damage includes, but is not limited to, 

dropping, exposure to excessive heat greater than 100ºF and water/liquid damage.

 

 

Repair or replacement of the system as provided under this warranty is the sole and 

exclusive remedy of the purchaser. MedRx shall not be liable for any consequential 

or incidental damages or for breach of any express or implied warranty. Except to the 

extent of applicable law, any implied warranty, merchantability or fitness of this 

product is limited to the duration of this warranty.

 

 

MedRx will, at its discretion, service and repair out of warranty products at the 

purchaser's request, charging for parts and labor as necessary.

 

 

The limited warranty is deemed void if software or hardware is installed on this 

product which is not pre-approved by MedRx, Inc. Approved software includes 

NOAH™ and HIMSA approved hearing aid manufacturer programming modules for 

fitting hearing aids.

 

 

MedRx, Inc is not responsible for problems resulting from installation of unapproved 

software or hardware. In the event of unapproved software or hardware installed on 

the system causing a conflict, MedRx will service the product for a fee to be 

determined at the time of service.

 

 

Any extension of this warranty past the initial one-year warranty is subject to the 

following (where applicable).

 

1.

 

A $300 deductible per repair.

 

2.

 

Extended warranty does not include cables, connectors or peripherals.

 

3.

 

Extended warranty of the Video Otoscope covers optics only.

 

Содержание UltraVac+

Страница 1: ...O P E R AT I N G I N S T R U C T I O N S HearingInstrumentRestorationSystem www medrx usa com ...

Страница 2: ...As with all of our products MedRx is pleased to provide the top notch service and support that you have come to expect Our associates constantly strive to see that every effort is put forth in satisfying your needs and requests I can assure you we will not waiver from this objective as we move into the future We are aware of what has made us one of our industry s leading equipment suppliers QUALIT...

Страница 3: ......

Страница 4: ...commended Procedure 7 Drying Chamber 8 Change Drying Chamber Filter 8 Vacuum Wand 8 Pressure Wand 9 Care and Maintenance 9 Troubleshooting Guide 12 Limited Warranty 13 Specifications 14 www medrx usa com 1200 Starkey Rd 105 Largo FL 33771 Toll Free 888 392 1234 727 584 9600 Fax 727 584 9602 Email medrx medrx usa com ...

Страница 5: ...lectrical shock or serious injury do not remove the white cover of this equipment Service should be performed by factory trained and authorized personnel BASIC OPERATION The UltraVac was designed to give dispensers and technicians a functional tool for repairing restoring and maintaining hearing aids It is easy to use which makes it ideal for those who may be just getting started and powerful enou...

Страница 6: ...atient any concerns they have with the operation of the aid Counsel patient on what you will be doing to improve or correct the problem If possible test the condition of the battery and if it is weak or dead replace it If the aid is dead or damaged have the patient acknowledge this before proceeding Remove Visible Wax Using the cleaning tool kit provided with the UltraVac clean any large visible a...

Страница 7: ...pear on the display Move the WAND CHAMBER switch to the WAND position to release the vacuum Remove the hearing aid s from the chamber upon completion The cycle can be ended prior to the 4 minute timer by pressing the STOP switch Then the chamber can be vented as described above or the re started with the time remaining on the display Moving the WAND CHAMBER switch to the WAND position during chamb...

Страница 8: ...for cleaning vacuum tips is included in the enclosed tool kit The wand assembly can be removed from the coupling on the base unit by pushing in the retaining ring and gently pulling on the tubing To reinstall simply insert the tubing back into the coupler CARE AND MAINTENANCE The UltraVac has been engineered to provide years of trouble free service There are no field serviceable components inside ...

Страница 9: ...first step before re use 1 Gather all equipment cleaning solutions and materials required to clean the patient care devices 2 WASH hands and put on gloves prior to cleaning the devices Personal protective equipment should be changed if torn or soiled Use protective eyewear during the cleaning procedure 3 Visible or gross soil present and or blood or body fluid spills must be removed prior to clean...

Страница 10: ... the exterior with Alcohol Swabs Immerse the hose in a bath of alcohol for 10 to 20 minutes lowering one end first to remove all the air from the hose The drying cup and chamber bottom may be cleaned with Alcohol Swabs After air drying run the system for 10 minutes and one drying chamber cycle to remove any residual alcohol The drying chamber filter is located in the center of the black rubber cha...

Страница 11: ...in panel Check to make sure filter is properly attached and not blocked Check to make sure tips on either hose are not blocked use the pressure function to clear tip Call for service Ensure that the switch is in the CHAMBER position Check to make sure vacuum cup does not leak around pad or has any cracks Call for service 888 392 1234 Caution To avoid the risk of electrical shock or serious injury ...

Страница 12: ...haser MedRx shall not be liable for any consequential or incidental damages or for breach of any express or implied warranty Except to the extent of applicable law any implied warranty merchantability or fitness of this product is limited to the duration of this warranty MedRx will at its discretion service and repair out of warranty products at the purchaser s request charging for parts and labor...

Страница 13: ... Volt 1 25 amp SB 5x20mm 220 Volt 2 50 amp SB 5x20mm Operating Temperature 0 to 50 C 32 to 120 F Weight Approx 8 5 lbs 5 kg Dimensions approx 10 5 w x 6 25 h x 12 d 26 6cm w x 16cm h x 30 4cm d Vacuum Tips 14 15 2 18 and 2 20 gauge w SafetyLok attachment Drying Chamber 4 minutes with auto shut off Cycle Time Vacuum Pressure Wand Continuous use ...

Страница 14: ...TheUltraVac SystemIncludes UtraVac BaseUnit PressureWand withHose VacuumWand withHose Filter 6VacuumWandTips Drying ChamberFilter InstructionManual CleaningToolKit DryingChamber ...

Отзывы: