background image

 

MedRx Avant Polar HIT 

 

 

AH-I-MPHITU-3 – Effective 05/31/2011 

 

18

Clinical Use of Polar Plots 
 

Integrating new technology into your daily routine takes a bit of time and effort, but being certain that your 
premium product line is in peak condition for every patient is well worth it.

 Testing each hearing 

instrument upon receipt in the Avant Polar HIT chamber provides you with the confidence to know that 
one of the key features in each patient’s hearing instrument fitting is functioning according to specification 

before the appointment is made.

  Identifying these problems and rescheduling is far better than sending 

a patient into the world with expectations that cannot be met. 

 

As of 2007, there have been many peer-reviewed scientific papers demonstrating the benefits of 
directional microphones for people with sensorineural hearing loss.  Further, the MarkeTrak surveys 
continue to show that discriminating speech in noise is one of the greatest challenges and most desired 
outcomes for people purchasing hearing instruments.   
 
The majority of hearing instrument manufacturers offer sophisticated directional microphone systems, 
however other data reveals that manufacturing and shipping mishaps result in a large percentage of 
instruments arriving at your office with malfunctioning directional microphones.   
 

Additionally, the Avant Polar HIT allows you to quickly and precisely diagnose when directional 
microphones fair or become misaligned after the sale.  This expedites the repair process and ensures 
your practice maintains the highest level of patient satisfaction and repeat business.  Finally, the Avant 
Polar HIT is also a comprehensive ANSI and IEC test chamber which allows you to also diagnose 
distortion, weak amplifiers and malfunctioning telecoils. 
 

 

Printing 

The AVANT POLAR HIT software allows you to print tests individually or as a complete multi-test report.   

Printing Individual Tests

 

Printing Multi-Test Reports

 

1. Click 

File 

2. Click 

Print 

 

 

 

1. Click 

File 

2.  Click Print Report 

 

 

Содержание Avant Polar HIT

Страница 1: ...USER MANUAL...

Страница 2: ...1 Testing Directional Hearing Instruments Polar Plots 12 Clinical Use of Polar Plots 18 Printing 18 Limited Warranty 19 0086 www medrx usa com 1200 Starkey Rd 105 Largo FL 33771 Toll Free 888 392 1234...

Страница 3: ...recision Hearing Instrument Testing for your office Compact yet rugged this PC Based system is USB powered and performs all required ANSI and IEC tests A unique feature of the Polar HIT is a rotating...

Страница 4: ...The AVANT Software Suite can run stand alone or from NOAH System or the TIMS NOAH Compatible Office System Figure 1 The AVANT Software Suite Main Screen Figure 2 The AVANT HIT Stand Alone Main Screen...

Страница 5: ...are The View tab allows you to set the default appearance of the HIT test environment Values can be changed by using the check boxes and pull down menus shown above The HIT Tab allows you to select th...

Страница 6: ...as shown to the right The key features of each tab are described below For more in depth information consult the interactive Help system within the software The General Tab configures the overall Avan...

Страница 7: ...truments 1 Seal acoustic vents 2 Wrap the canal portion of the instrument with a hermetic sealing material such as Bostik Blu Tack see Figure 1 3 Align the sound bore with the opening of the ITE coupl...

Страница 8: ...to 20mm long Tygon tube on BTE Coupler Adapter see Figure 4 3 Snap the BTE Coupler Adapter onto the 2cc Coupler see Figure 5 Figure 4 Figure 5 Hearing Instruments with Button Receivers 1 Remove earmo...

Страница 9: ...hone Proper positioning for ITE BTE and Body Worn hearing instruments are shown below ITE Hearing Instrument BTE Hearing Instrument Body Worn Hearing Instrument Once the instrument is properly placed...

Страница 10: ...nclude in your Auto Test battery 4 Select the appropriate amplifier and battery type 5 Select the test frequencies you wish to use 6 Select your default stimulus For ANSI and IEC tests select Tone To...

Страница 11: ...strate the Avant Polar HIT representations of the ANSI S3 22 2003 Hearing Instrument Test Battery The system also supports the IEC 60118 7 2005 OSPL90 Full On Gain Reference Test Gain Frequency Respon...

Страница 12: ...ic vents 2 Wrap the canal portion of the instrument with a hermetic sealing material such as Bostik Blu Tack see Figure 1 3 Align the sound bore with the opening of the ITE coupler adapter Press the s...

Страница 13: ...nce the instrument is properly placed in the test chamber turn the power on and close the lid of the chamber The latch will engage which an audible click when the lid is closed properly Notes 4 ITE in...

Страница 14: ...he software will prompt you to manually rotate the test pad either clockwise or counter clockwise Please refer to the figure below for reference 7 Follow the screen prompts circled in red below to com...

Страница 15: ...tivity when the test signal 1000 Hz pure tone is in front of the hearing instrument 750 The minimum sensitivity or null of the system occurs between 1050 and 1200 to either side of the center of the h...

Страница 16: ...ress Start Directionality test gauge is shown indicating current position inside the box 2 Press Test and wait for the test to finish The test is performed automatically Target and current positions a...

Страница 17: ...Zero angle is assumed when the hearing aid microphone is facing the main right speaker The Current box indicates the current angle The table can be rotated either by using the Left and Right arrows or...

Страница 18: ...iscriminating speech in noise is one of the greatest challenges and most desired outcomes for people purchasing hearing instruments The majority of hearing instrument manufacturers offer sophisticated...

Страница 19: ...ded under this warranty is the sole and exclusive remedy of the purchaser MedRx shall not be liable for any consequential or incidental damages or for breach of any express or implied warranty Except...

Отзывы: