background image

OPERATION AND 

MAINTENANCE MANUAL

ALTERRA 1385, LONG TERM CARE BED

FCE1385B

This product is not made with natural rubber latex.
Packaging / Handling Instructions see Page 8.

(Shown with optional side rails, mattress, head/footboards, pillows, and comforter)

Содержание ALTERRA 1385

Страница 1: ...CE MANUAL ALTERRA 1385 LONG TERM CARE BED FCE1385B This product is not made with natural rubber latex Packaging Handling Instructions see Page 8 Shown with optional side rails mattress head footboards...

Страница 2: ...cific potential entrapment zones in hospital bed systems Hospital Bed System Dimensional and Assessment Guidance to Reduce Entrapment The entrapment zones represent the relationship of the various bed...

Страница 3: ...IS BED WITHOUT FIRST READING AND UNDERSTANDING THIS MANUAL IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS CAUTIONS AND INSTRUCTIONS CONTACT YOUR MEDLINE SALES REP OR MEDLINE CUSTOMER SERVICE BEFORE USIN...

Страница 4: ...r transferring in or out of bed DO NOT ALTER THE PLUG ON THE ELECTRICAL CORD If the plug does not fit the existing outlet a correct outlet should be installed by a licensed electrician NEVER operate t...

Страница 5: ...into the head section H frame using a rubber mallet if necessary INSTALLING OPTIONAL HEAD AND FOOTBOARDS Tools Required Philips Screw Driver Rubber Mallet Materials Required Head and Footboards and H...

Страница 6: ...nt 2 C Clips 2 Locate and install C clips into grooves on the rods of the head section assist rails until they are fully engaged Place C clips on each side of the deck section rod tab as shown below 3...

Страница 7: ...in bodily injury The battery back up is a factory sealed unit DO NOT ATTEMPT to open repair unit Contains sealed lead battery Battery must be recycled REPLACING BATTERY Tools Required Flat Head Screw...

Страница 8: ...place power cord Grinding noise heard from one of the actuators Actuator gear is stripped Actuator gear is stripped replace actuator Replace actuator TROUBLESHOOTING CONTINUED Symptom Possible Cause R...

Страница 9: ...work platform 1 Remove all accessories mounted to the bed assist rails assist bars and head and footboards 2 Elevate the bed to its highest position and raise the head and foot sections 3 Unplug the...

Страница 10: ...Section Bed Deck 17 FCE1385017 1 Wall Guard 18 FCE1385018 1 Head Section H Frame 19 FCE1385019 1 Foot Section H Frame 20 FCE1385020 1 Thigh Section Bed Deck 21 FCE1385021 2 Leg Assembly 22 FCE1385022...

Страница 11: ...y examine all welds for cracks 3 Inspect the deck components for any bending damage or excessive wear 4 Check the ends of the actuators and mounting hardware for any bending damage or excessive wear 5...

Страница 12: ......

Страница 13: ...ir Installation and freight costs for replaced or repaired items remain the responsibility of the Customer This warranty does not cover failure due to negligence accident deliberate abuse nor improper...

Отзывы: