26
Steps to take:
1. Check to see if the O2 Control knob is not fully closed.
2. If it is, turn the O2 Control knob up. Press Power twice to switch the device off and on again. After 40
seconds, check to see if the device operates back in normal mode (without the fault status above). The fault
is resolved when the device is operating in normal mode after 40 seconds.
3. If it is not, press Power to switch the device off and contact the nearest Medklinn service centre to arrange
for maintenance service immediately.
Controlling the Active Oxygen emission rate
The Medklinn PRO AS1000D Active Oxygen emission rate is set depending on the total coverage area. It is
controlled by 3 different methods:
1. O2 Control
- Turning the knob of the O2 Control to increase or decrease the level of Active Oxygen generation
Before: O2 Control
when device is at rest
After: O2 Control when device
is in operation
Knob
Turn
Ball Bearing
Ball Bearing is floating