GENERAL INFORMATION

READ THESE INSTRUCTIONS COMPLETELY BEFORE INSTALLING THE PRODUCTS. FAILURE TO DO SO  COULD RESULT IN  AN 

IMPROPER INSTALLATION AND COULD VOID THE WARRANTY.

RESPONSIBILITY OF THE INSTALLER

THE INSTALLER MUST INSPECT AND WATER-TEST THE PRODUCT PRIOR TO INSTALLATION TO ENSURE THE UNIT IS FREE 

OF DEFECT OR DAMAGE. IN THE EVENT OF A PROBLEM, THE UNIT MUST NOT BE INSTALLED. IF THE CRATE OR THE PRODUCT 

HAS BEEN DAMAGED DURING SHIPPING, PLEASE CALL US IMMEDIATELY.

THIS PRODUCT MUST BE INSTALLED BY A LICENSED/CERTIFIED CONTRACTOR

LICENSED  PLUMBERS  AND  ELECTRICIANS  SHOULD  BE  EMPLOYED  TO  INSURE  PROPER  INSTALLATION.  INSTALLERS 

ASSUME  ALL  LIABILITY  FOR  THE  CORRECT  INSTALLATION  PROCEDURES.  ONLY  ACCESSORIES  AUTHORIZED  BY  THE 

MANUFACTURER SHOULD BE USED WITH THIS PRODUCT.

IMPORTANT SAFETY INSTRUCTIONS

WARNING!

 WHEN USING THIS PRODUCT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED. 

READ AND FOLLOW ALL INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRICAL SHOCK, AND/

OR OTHER INJURIES.

SA

VE 

TH

IS 

M

ANUA

L

UNPACKING

UN

PA

CK

IN

G

UNPACKING THE UNIT

INSPECTING THE PACKAGING

Inspect the carton. If any damages are noted, photograph the damaged area(s) and notify the deliverer/carrier.

LIFTING / TRANSPORTING

Never lift the walk-in bathtub by the plumbing. Doing so may result in damaging the plumbing and causing a leak. 

INSPECTING THE UNIT

Immediately inspect the unit for damage even if there is no carton damage. Once the unit is installed surface damages will be 

assumed to be installation related if not reported at this point. 

PLACING THE UNIT

Please note that an installer(s) assumes full liability for damages to the walk-in bathtub after the unit is installed in the “

cradle”/ niche. 

Содержание 3060WCA

Страница 1: ...W H E R E S A F E T Y M E E T S L U X U R Y INSTALLATION OPERATING INSTRUCTIONS INSTALLATION OPERATINGINSTRUCTIONS 3060WCA MODEL www agingsafelybaths com ...

Страница 2: ...PRE INSTALLATION 6 INSTALLATIONPREPARATION 7 ELECTRICALPREPARATION 8 INSTALLATIONPROCEDURES 9 DRAINCONNECT ION 10 CONNECT INGTHE AUTODRA IN 11 INSTALLATIONANDEXTENS IONPANELS 12 FAUCETINSTALLATION 13 OPERATINGSAFETY INSTRUCTIONS 14 OPERATINGINSTRUCTIONS 16 TUBCONTROLS 18 CLEANINGANDMAINTENANCE 19 WARRANTY 20 RETURN POLICY 22 PRODUCTREGISTRATIONCARD 23 TABLE OF CONTENTS TABLE OF CONTENTS ...

Страница 3: ...1060 info meditub com http www meditub com THANK YOU CONTACT PRODUCT REGISTRATION PRODUCT REGISTRATION PRODUCTREGISTRATION ToensurethatyourwarrantyisregisteredwithMeditubWalk InBathtubs complete signandreturnthisregistrationcardwithin30daysofthepurchase NOTE Yourwarrantywillnotberecognized byMeditubWalk InBathtubs unlessthiscardisfullycompletedandreturnedto MeditubWalk InBathtubs 5701NW35thAve Mia...

Страница 4: ...TY FOR THE CORRECT INSTALLATION PROCEDURES ONLY ACCESSORIES AUTHORIZED BY THE MANUFACTURERSHOULDBEUSEDWITHTHISPRODUCT IMPORTANTSAFETYINSTRUCTIONS WARNING WHENUSINGTHIS PRODUCT BASICPRECAUTIONSSHOULDALWAYS BEFOLLOWED READANDFOLLOWALLINSTRUCTIONSPERTAININGTORISKOFFIRE ELECTRICALSHOCK AND OROTHER INJURIES SAVE THIS MANUAL UNPACKING UNPACKING UNPACKINGTHE UNIT INSPECTINGTHE PACKAGING Inspectthecarton ...

Страница 5: ...theunionsandinsuretheO ringisseatedproperly NOTE IFTHEPUMPSDONOTOPERATE CHECKTHEBREAKERTOENSUREPOWER ISONANDTHECABLECONNECT INGTHE CONTROLSTOTHEPUMP ISATTACHED WARNING DO NOT RUN ANY PUMPS UNLESS THE TUB IS FILLED WITH WATER TO PROPER LEVEL DAMAGEDUETODRYRUNNINGPUMPS IS NOTCOVEREDUNDERWARRANTY FAILURETO PERFORMTHESETESTSBE FORE INSTALLATIONWILL MAKETHE INSTALLERLIABLEFORFUTURE REPAIRCOSTS INSTALLA...

Страница 6: ...ssage Or Air Massage w Light 15 Amp GFCI Jet Massage Or Air Massage w Auto Drain 15 Amp GFCI Jet Massage Or Air Massage w Light Auto Drain 15 Amp GFCI Jet Massage Air Massage Dual 20 Amp GFCI Jet Massage Air Massage Dual w Light 20 Amp GFCI Jet Massage Air Massage Dual w Auto Drain 20 Amp GFCI Jet Massage Air Massage Dual w Light Auto Drain 20 Amp GFCI Whirlpool Inline Heater Dedicated 15 Amp Circ...

Страница 7: ...ies Once thehoseisinplace closethedoorontheunit placethehandleinthelockedposi tion andfilltubwithatleast12 ofwatertotesttheconnection Oncethecompletion of the drain components are installed and have been tested for proper function the unit can be leveled and give a final water test beforeinstallationofunit Figure2 1 1 2 Door Drain Pipe supplied 7 1 2 FIGURE1 Floor Drain Incorrect Flow Door Drain C...

Страница 8: ...S L U X U R Y FAUCETINSTALLATION fixing nut fixing nut fixing nut hot control handle cold control handle spout shower head diverter rubber washer fiber washer valve body gasket steel braded 19 hose steel braded 19 hose 72 shower hose local water line hot water cold water SIDE ACCESS PANELS FOR 3 SIDE ENCLOSURE ASSEMBLY PLACEMENT Verifyaccesstounit ssystemfromoneofthesideenclosures ...

Страница 9: ...our feetofthisbathtub Neverdroporinsertanyobjectsintoanyopenings Donotoperatethisunitwithouttheguardoverthesuctionfittings WARNING RISKOF HYPERTHERMIAANDPOSSIBLEDROWNING Peopleusingmedications herbalremedies sleepaids and orhavingadversemedicalhistoryshouldconsultaphysicianbeforeusingthisproduct WARNING NOFOODORALCO HOLICBEVERAGES Useofyourbathtubimmediatelyaftermealsisnotrecommended Avoid alcohol...

Страница 10: ...zlefordirection Turneithertheoutsideringorthenozzleclockwise orcounterclockwiseforflow somejetsadjusttheflowwiththeoutsideringandsomewiththenozzle Adjusttheairpressureflow ofallwaterjetsbyusingthe airvolumecontrol seepage18 whichcontrolsair watermixture Meditubwalk intubsequippedwiththechromotherapylights orderedseparately featureadedicatedon offswitch Pressingthe switchoffandbackonwillchangetheco...

Страница 11: ...placeasneeded 1 2 3 4 6 5 Controlsdepictedmayvaryfromthosefoundonyourunit Varianceisbasedonthe optionspurchasedduringtheorderprocess CLEANINGANDMAINTENANCE Pumpandpipecirculationsystemsshouldbeflushedbeforefirstuseandonamonthlybasiswhenproductisundernormaluse Belowaretherecommendedproceduresforcleaning Do notrunwhirlpooldry Fill thetubwithhotwater2 3 inchesabovethejets andadd2 3 teaspoonsof lowfoa...

Страница 12: ...a charge for replacement parts or the replacement of the entire electrical unit if the defective unit is returned for any of the reasons listed above NOTE WITHIN THE LIMITED ONEYEAR WARRANTY THERE WILL BE A PRORATED CHARGE FOR ANY ELECTRICAL AND PLATEDREPLACEMENTSPARTS INCLUDINGSHIPPINGANDHANDLINGCHARGES Manufacturer reserves the sole authority to make any type of warranty changes at any time The ...

Страница 13: ...Allreturnswillreceivea 15 restockingfeeplusall freightcostsoftheoriginalshipmentandreturnshipmenttoMeditubWalk InBathtubs AllrequestsforreturnmustfirstbeapprovedbyMeditubWalk InBathtubs andhaveanassigned ReturnedMerchandise Authorizationnumber RMA RETURN POLICY RETURN POLICY Meditub Walk InBathtubs Product Registration Card Name Address City State Zip Phone Date of Purchase Dealer Address Installe...

Страница 14: ...W H E R E S A F E T Y M E E T S L U X U R Y INSTALLATION OPERATINGINSTRUCTIONS INSTALLATION OPERATING INSTRUCTIONS W H E R E S A F E T Y M E E T S L U X U R Y ...

Отзывы: