W H E R E   S A F E T Y   M E E T S   L U X U R Y

INS

TALL

AT

ION

  &

  OPER

AT

ING

  INSTRUC

TI

ON

S

INSTALLATION & OPERATING INSTRUCTIONS

3060WCA

MODEL

www.agingsafelybaths.com

Содержание 3060WCA

Страница 1: ...W H E R E S A F E T Y M E E T S L U X U R Y INSTALLATION OPERATING INSTRUCTIONS INSTALLATION OPERATINGINSTRUCTIONS 3060WCA MODEL www agingsafelybaths com ...

Страница 2: ...PRE INSTALLATION 6 INSTALLATIONPREPARATION 7 ELECTRICALPREPARATION 8 INSTALLATIONPROCEDURES 9 DRAINCONNECT ION 10 CONNECT INGTHE AUTODRA IN 11 INSTALLATIONANDEXTENS IONPANELS 12 FAUCETINSTALLATION 13 OPERATINGSAFETY INSTRUCTIONS 14 OPERATINGINSTRUCTIONS 16 TUBCONTROLS 18 CLEANINGANDMAINTENANCE 19 WARRANTY 20 RETURN POLICY 22 PRODUCTREGISTRATIONCARD 23 TABLE OF CONTENTS TABLE OF CONTENTS ...

Страница 3: ...1060 info meditub com http www meditub com THANK YOU CONTACT PRODUCT REGISTRATION PRODUCT REGISTRATION PRODUCTREGISTRATION ToensurethatyourwarrantyisregisteredwithMeditubWalk InBathtubs complete signandreturnthisregistrationcardwithin30daysofthepurchase NOTE Yourwarrantywillnotberecognized byMeditubWalk InBathtubs unlessthiscardisfullycompletedandreturnedto MeditubWalk InBathtubs 5701NW35thAve Mia...

Страница 4: ...TY FOR THE CORRECT INSTALLATION PROCEDURES ONLY ACCESSORIES AUTHORIZED BY THE MANUFACTURERSHOULDBEUSEDWITHTHISPRODUCT IMPORTANTSAFETYINSTRUCTIONS WARNING WHENUSINGTHIS PRODUCT BASICPRECAUTIONSSHOULDALWAYS BEFOLLOWED READANDFOLLOWALLINSTRUCTIONSPERTAININGTORISKOFFIRE ELECTRICALSHOCK AND OROTHER INJURIES SAVE THIS MANUAL UNPACKING UNPACKING UNPACKINGTHE UNIT INSPECTINGTHE PACKAGING Inspectthecarton ...

Страница 5: ...theunionsandinsuretheO ringisseatedproperly NOTE IFTHEPUMPSDONOTOPERATE CHECKTHEBREAKERTOENSUREPOWER ISONANDTHECABLECONNECT INGTHE CONTROLSTOTHEPUMP ISATTACHED WARNING DO NOT RUN ANY PUMPS UNLESS THE TUB IS FILLED WITH WATER TO PROPER LEVEL DAMAGEDUETODRYRUNNINGPUMPS IS NOTCOVEREDUNDERWARRANTY FAILURETO PERFORMTHESETESTSBE FORE INSTALLATIONWILL MAKETHE INSTALLERLIABLEFORFUTURE REPAIRCOSTS INSTALLA...

Страница 6: ...ssage Or Air Massage w Light 15 Amp GFCI Jet Massage Or Air Massage w Auto Drain 15 Amp GFCI Jet Massage Or Air Massage w Light Auto Drain 15 Amp GFCI Jet Massage Air Massage Dual 20 Amp GFCI Jet Massage Air Massage Dual w Light 20 Amp GFCI Jet Massage Air Massage Dual w Auto Drain 20 Amp GFCI Jet Massage Air Massage Dual w Light Auto Drain 20 Amp GFCI Whirlpool Inline Heater Dedicated 15 Amp Circ...

Страница 7: ...ies Once thehoseisinplace closethedoorontheunit placethehandleinthelockedposi tion andfilltubwithatleast12 ofwatertotesttheconnection Oncethecompletion of the drain components are installed and have been tested for proper function the unit can be leveled and give a final water test beforeinstallationofunit Figure2 1 1 2 Door Drain Pipe supplied 7 1 2 FIGURE1 Floor Drain Incorrect Flow Door Drain C...

Страница 8: ...S L U X U R Y FAUCETINSTALLATION fixing nut fixing nut fixing nut hot control handle cold control handle spout shower head diverter rubber washer fiber washer valve body gasket steel braded 19 hose steel braded 19 hose 72 shower hose local water line hot water cold water SIDE ACCESS PANELS FOR 3 SIDE ENCLOSURE ASSEMBLY PLACEMENT Verifyaccesstounit ssystemfromoneofthesideenclosures ...

Страница 9: ...our feetofthisbathtub Neverdroporinsertanyobjectsintoanyopenings Donotoperatethisunitwithouttheguardoverthesuctionfittings WARNING RISKOF HYPERTHERMIAANDPOSSIBLEDROWNING Peopleusingmedications herbalremedies sleepaids and orhavingadversemedicalhistoryshouldconsultaphysicianbeforeusingthisproduct WARNING NOFOODORALCO HOLICBEVERAGES Useofyourbathtubimmediatelyaftermealsisnotrecommended Avoid alcohol...

Страница 10: ...zlefordirection Turneithertheoutsideringorthenozzleclockwise orcounterclockwiseforflow somejetsadjusttheflowwiththeoutsideringandsomewiththenozzle Adjusttheairpressureflow ofallwaterjetsbyusingthe airvolumecontrol seepage18 whichcontrolsair watermixture Meditubwalk intubsequippedwiththechromotherapylights orderedseparately featureadedicatedon offswitch Pressingthe switchoffandbackonwillchangetheco...

Страница 11: ...placeasneeded 1 2 3 4 6 5 Controlsdepictedmayvaryfromthosefoundonyourunit Varianceisbasedonthe optionspurchasedduringtheorderprocess CLEANINGANDMAINTENANCE Pumpandpipecirculationsystemsshouldbeflushedbeforefirstuseandonamonthlybasiswhenproductisundernormaluse Belowaretherecommendedproceduresforcleaning Do notrunwhirlpooldry Fill thetubwithhotwater2 3 inchesabovethejets andadd2 3 teaspoonsof lowfoa...

Страница 12: ...a charge for replacement parts or the replacement of the entire electrical unit if the defective unit is returned for any of the reasons listed above NOTE WITHIN THE LIMITED ONEYEAR WARRANTY THERE WILL BE A PRORATED CHARGE FOR ANY ELECTRICAL AND PLATEDREPLACEMENTSPARTS INCLUDINGSHIPPINGANDHANDLINGCHARGES Manufacturer reserves the sole authority to make any type of warranty changes at any time The ...

Страница 13: ...Allreturnswillreceivea 15 restockingfeeplusall freightcostsoftheoriginalshipmentandreturnshipmenttoMeditubWalk InBathtubs AllrequestsforreturnmustfirstbeapprovedbyMeditubWalk InBathtubs andhaveanassigned ReturnedMerchandise Authorizationnumber RMA RETURN POLICY RETURN POLICY Meditub Walk InBathtubs Product Registration Card Name Address City State Zip Phone Date of Purchase Dealer Address Installe...