Mounting

1

INSTALLATION

Dismantling for installation

• The dryer is supplied with a pressure-mounted cover, and is not screwed down.

• The 4 attachment screws are provided in the bag with the plugs and lag bolts.

• Remove the cover vertically from the machine supporting base, taking care to avoid:

- Damaging the internal components.

- Damaging the cover. We recommend resting it on a flat   surface with the visible part upwards, or on

top of a cloth.

• Mount the machine along the rear channels.

• Insert the electric ducting through the hole next to the terminal strip.

• Use the drill template provided to fix the dryer to the wall.

• Drill 4 holes with a diameter of 5/16” (8 mm), and take care to clean all traces of dust from the holes.

• Screw down the base firmly to the wall using a flat ended screwdriver of 1/4" (6÷7 mm).

• Connect the electric ducting to the terminal strip. Screw down the 3 locking screws firmly.

Hole for the insertion of the electric ducting.

CAUTION: do not damage the ir sensors in automatic models

Содержание M88-UL

Страница 1: ... USA SANIFLOW CORPORATION 2655 LeJeune Rd Suite 810 Coral Gables FL 33134 Tel 305 424 24 33 Fax 305 424 24 35 info saniflowcorp com www saniflowcorp com SPAIN MEDICLINICS S A Industria 54 E 08025BARCELONA Tel 34 93 446 47 00 Fax 34 93 348 10 39 info mediclinics com www mediclinics com Cod 92915UL ...

Страница 2: ...e with the visible part upwards or on top of a cloth Mount the machine along the rear channels Insert the electric ducting through the hole next to the terminal strip Use the drill template provided to fix the dryer to the wall Drill 4 holes with a diameter of 5 16 8 mm and take care to clean all traces of dust from the holes Screw down the base firmly to the wall using a flat ended screwdriver of...

Страница 3: ...duct in a safe and reasonable manner and d repair of the product by unauthorized personnel LIMITATION ON LIABILITY THE WARRANTY SET FORTH ABOVE IS EXCLUSIVE AND NO OTHER WARRANTY WHETHER WRITTEN OR ORAL IS EXPRESSED OR IMPLIED MEDICLINICS S A SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL MEDICLINICS S A BE LIABLE FOR INDIREC...

Страница 4: ... 10 15 cm Automatic models These models operate by hand detection If hands are held 4 6 10 15 cm from the air discharge nozzle the dryer will start working and will stop 2 3 seconds after use If the sensor is blocked due to vandalism the dryer will completely stop working Please concerning automatic models let a minimum separation of 16 40 cm between appliance and any shelf marble worktop or washb...

Отзывы: