Mediclinics JUNIOR PLUS Скачать руководство пользователя страница 13

 

 

 

Disconnect the electronic circuit board from the grid. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disconnect the four cables; two from the motor (red and brown) and two from the 

heating element (white), from the terminal block of the electronic circuit board. 

Содержание JUNIOR PLUS

Страница 1: ...nance action 3 Exercising care in accordance with the procedures included herein General maintenance Preventive Maintenance Cleaning Inspect the units annually or quarterly depending on the dryer s operating cycles Clean the active parts of the unit such as the motor the heating element the fan and the electronic circuit board with a soft brush In automatic versions clean the infrared sensor with ...

Страница 2: ...s prior to carrying out any work on the unit Release the screws that attach the casing 4 units with a Phillips head screwdriver Remove the casing from the base To avoid scratching the casing place it on a flat surface with the visible part facing upward ...

Страница 3: ...pm Class F Maintenance As preventive maintenance we recommend using a soft brush to remove dust and dirt on an annual or bi annual basis depending on the dryer s operating cycles Replacement of the motor Automatic version Loosen the nut that secures the fan to the drive shaft ...

Страница 4: ...xagonal spanner separate the base from the rear cover by applying a slight pressure on the four clips Disconnect the two cables from the motor red and brown that go to the terminal block of the electronic circuit board ...

Страница 5: ...With a 7 mm hexagonal spanner loosen the screws located at the crosspiece of the base Remove the motor from its location and replace it Fit it by following the previous steps in reverse order ...

Страница 6: ...Push button version Loosen the nut that secures the fan to the drive shaft Using an 8 mm hexagonal spanner separate the base from the rear cover by applying a slight pressure on the four clips ...

Страница 7: ...With a 7 mm hexagonal spanner loosen the screws located on the crosspiece of the base Disconnect the two cables from the motor red and brown that go to the terminal block of the timer ...

Страница 8: ...e order Heating element Characteristics Heating element 1 500 W Coiled NiCr heating element On MICA body Includes a thermal limiter Maintenance As preventive maintenance we recommend using a soft brush to remove dust and dirt on an annual or bi monthly basis depending on the dryer s operating cycles ...

Страница 9: ... version Using an 8 mm hexagonal spanner separate the base from the rear cover by applying a slight pressure on the four clips Disconnect the two cables from the heating element white that go to the terminal block of the electronic circuit board ...

Страница 10: ...ion by bending the fastening clip and replace it Fit it by following the previous steps in reverse order Push button version Using an 8 mm hexagonal spanner separate the base from the rear cover by applying a slight pressure on the four clips ...

Страница 11: ...rom the heating element white which are located in the terminal block of the timer Remove the heating element from its location by bending the fastening clip and replace it Fit it by following the previous steps in reverse order ...

Страница 12: ...on distance Maintenance As preventive maintenance we recommend using a soft brush to remove dust and dirt on an annual or bi annual basis depending on the dryer s operating cycles Additionally you should regularly clean the LEDs with a cloth dampened with alcohol Replacement of the electronic circuit board Using an 8 mm hexagonal spanner separate the base from the rear cover by applying a slight p...

Страница 13: ...connect the electronic circuit board from the grid Disconnect the four cables two from the motor red and brown and two from the heating element white from the terminal block of the electronic circuit board ...

Страница 14: ... housing carefully freeing it from its four anchoring points and replace it Fit it by following the previous steps in reverse order Setting the detection distance Position of the jumper at high sensitivity detection distance between 20 and 25 cm ...

Страница 15: ...low sensitivity position The lighting conditions of the installation site can alter the detection distances Push button version Characteristics Electronic timer 45 cycle Maintenance As preventive maintenance we recommend using a soft brush to remove dust and dirt on an annual or bi annual basis depending on the dryer s operating cycles ...

Страница 16: ...n 8 mm hexagonal spanner separate the base from the rear cover by applying a slight pressure on the four clips Disconnect the cables from the motor red and brown and the heating element white that go to the terminal block of the timer ...

Страница 17: ...o timer cables that go to the button Remove the timer from its location carefully freeing it from its four anchoring points using a flat tipped tool and replace it Fit it by following the previous steps in reverse order ...

Отзывы: