-12-
Care must be taken during this operation not to touch the electronic
circuit that is housed under the column with the cover.
NOTE: a minimum distance of 40 cm (15.75") must be allowed between
any possible shelves,marble or washbasins (see figure 11).
As far as possible, reflecting surfaces should be avoided within the
operating range of the IR sensors.
The appliance should only be handled by qualified personnel.
WARNING: when the cover is removed, live parts of the appliance
are exposed.
Means for discconection with contact separations at least 3 mm
(0.12") must be incorporated in the fixing wiring.
During the installation process, the protection areas should be
considered according to Norm VDE 0100. The hand-dryer must
only be installed on a closed surface, such as a wall, partition or
similar.
Automatic models
H - Heating element
M - Motor
S - Sensor
G - Ground
Pushbotton models
H - Heating element
M - Motor
T - Timer
G - Ground
WIRING DIAGRAM