Your computer must be set to use the 192.168.0.11 private IP address on subnet 255.255.255.0.
You must use an IPv4 Network.
Make sure that your network connection is working.
Steps
Wear an ESD wrist strap, ensuring it makes good contact with your bare skin.
Attach the ESD wrist strap end to an earth ground (unpainted bare metal spot of a grounded equipment rack).
Make sure the circuit breakers of AC power sources used to power the Mediatrix unit are OFF.
Make sure the provided external Power Adaptor is connected to the DC connector of the Mediatrix unit and in an appropriate AC electrical outlet.
Connect a 10/100 BaseT Ethernet RJ-45 cable into the
Ethernet connector of the Mediatrix unit.
LAN
Connect the other end of the cable into your PC.
Validate the installation.
Turn ON the AC power sources that are used to power the Mediatrix unit at the circuit breaker.
Note: When the unit is brought from a cold to a warm environment, condensation, that might be harmful to the unit, may occur. If this is the case,
wait one hour before connecting the power cord.
Result
You can now use the 192.168.0.10 IP address to access your unit's management interface.
Next Step
Top
Verifying the Installation
Steps
Contact the Mediatrix unit via the Web Browser, or go to step 2
In your Web browser, enter the IP address used by your Mediatrix unit to communicate with the Web interface.
If your computer is connected to the Ethernet port, commonly used to be connected to the Local Area Network (LAN), i.e. ETH2
on most devices, use the 192.168.0.10 IP address
If your Mediatrix unit is configured to use a DHCP server with IPv4, use the provided DHCP server IP address.
Enter
as your username and leave the password field empty.
public
Note: The
username account has administrator rights.
public
Note: You can also use
as a username and
as password.
admin
administrator
Click
.
Login
Contact the Mediatrix unit with an SNMP browser, or
Contact the Mediatrix unit via the CLI, or
Ping the Mediatrix unit.
Top
Cables
FXS Connections (RJ-11)
Caution: The RJ-11 cable should comply with UL 1863 and CSA C22.2 No 233 standards.
Caution: Use standard telecommunication cables with a minimum of 26 AWG wire gauge.
Note: The maximum standard FXS cable length is 450 m.
The RJ-11 pair of wires is wired so that pins 3 and 4 are connected to the Ring and Tip, which meets the EIA/TIA-IS 968 and CS-03 Issue 8, Part III
requirements.
Pin # Function
1
Not used
2
Not used
3
Ring
4
Tip
5
Not used
6
Not used
Top
10/100 Ethernet Connection (RJ-45)
Caution: Always use standard telecommunication cables with a minimum of 26 AWG wire gauge.
Category 5 cables can be used for 10/100 Base T-Connections.