![Media5 Mediatrix G7 Series Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/media5/mediatrix-g7-series/mediatrix-g7-series_hardware-installation-manual_1760479015.webp)
Model M - Mediatrix G7 Series
15
LEDs
#
LED
Behavior
Condition
Green, blinking, 1 cycle per
second, 50% duty
Unit is being restarted
Green, steady ON
Unit is restarted
1
Power
OFF
No current or failing power
supply
Green, steady ON
All lines are enabled
(operational state)
OFF
All lines are disabled
(operational state)
2
Ready
Blinking 1 cycle per 4
seconds, 75% duty
At least one line is enabled
and at least one line is
disabled (operational state)
OFF
Lines idled and unlocked
Yellow, steady ON
Lines in use and unlocked
3
In-Use
Yellow, blinking yellow, 1
cycle per second, 50% duty
Locked
Amber, steady ON
Indicates that the PRI port is
in use.
7
IN-USE
OFF
Indicates that the PRI port is
not connected.
Green, steady ON
Indicates that the PRI port is
well connected
8
LINK
Amber, steady ON
Indicates that the PRI port is
not connected
Red, steady ON
Indicates that the PRI port is
not working properly
10
ERROR/TROUBLE
OFF
Indicates that the PRI port is
working properly
Green, blinking, variable
rate
Network traffic
Green, steady ON
No network traffic
13
ETH1 - Right LED (activity)
OFF
Not connected
OFF
10 Mbps
13
ETH1 -Left LED (speed)
Green
100 Mbps
media5corp.com