1.
2
Transmit #1 (-) Receive #1 (-)
3
Not connected Not connected
4
Receive #2 (+) Transmit #2 (+)
5
Receive #1 (-) Transmit #1 (-)
6
Not connected Not connected
7
Not connected Not connected
8
Not connected Not connected
Top
FXS
Connections (RJ-11)
and FXO
Caution: The RJ-11 cable should comply with UL 1863 and CSA C22.2 No 233 standards.
Caution: Use standard telecommunication cables with a minimum of 26 AWG wire gauge.
Note: The Ringer Equivalence Number (REN) is 0.1. for each individual FXO port of the unit.
Note: The maximum standard FXS cable length is 450 m.
The RJ-11 pair of wires is wired so that pins 3 and 4 are connected to the Ring and Tip, which meets the EIA/TIA-IS 968 and CS-03 Issue 8, Part III
requirements.
Pin # Function
1
Not used
2
Not used
3
Ring
4
Tip
5
Not used
6
Not used
Top
BRI S/T Connection (RJ-48)
Caution: Always use standard telecommunication cables with a minimum of 26 AWG wire gauge.
BRI S/T connections use two pairs of wires: one pair for transmission and the second pair for reception. It is wired so that pins 3 and 6 are on one twisted
pair and pins 4 and 5 are on a second pair according to common wiring standards which meet the TIA/EIA 568A and 568B requirements.
Caution: The Mediatrix unit ISDN BRI ports are configurable to operate as network or terminal ports. The pin-out of the sockets is switched according to
this configuration. Wrong port configurations, wrong cabling or wrong connections to neighbouring equipment can lead to short circuits in the BRI line
powering.
Pin# TE mode
NT mode
1
Not Connected Not Connected
2
Not Connected Not Connected
3
Tx +
Rx +
4
Rx +
Tx +
5
Rx -
Tx -
6
Tx -
Rx -
7
Not connected Not Connected
8
Not connected Not Connected
Top
Troubleshooting
Locating the Product Serial Number
Before you begin
Warning: Make sure your unit is powered off.
Steps