2.3.

 

Installing

 

the

 

Device

 

 

Medexpert

 

CBPM24

 

is

 

a

 

battery

 

operated

 

device.

 

 

Insert

 

4

 

durable

 

alkaline

 

AA

 

batteries

 

into

 

the

 

Device

 

with

 

taking

 

care

 

of

 

the

 

right

 

polarity

 

(see

 

Figure

 

4)

 

 

Or

 

insert

 

4

 

AA

 

sized

 

rechargeable

 

Ni

MH

 

or

 

NiCd

 

batteries

 

as

 

per

 

the

 

above

 

instruction.

 

(Please

 

note

 

that

 

new

 

batteries

 

must

 

be

 

pre

charged.)

 

o

 

For

 

problem

free

 

operation

 

minimum

 

1,500

 

mAh

 

chargeable

 

Ni

MH

 

or

 

NiCd

 

batteries

 

are

 

recommended.

 

 

 

Figure

 

4.

 

 

The

 

Ni

MH,

 

NiCd

 

batteries

 

are

 

rechargeable

 

approximately

 

one

 

thousand

 

times.

 

If

 

the

 

capacity

 

of

 

the

 

rechargeable

 

batteries

 

is

 

low,

 

it

 

is

 

shown

 

on

 

the

 

LCD

 

automatically.

 

In

 

this

 

case

 

please,

 

change

 

all

 

the

 

four

 

batteries

 

not

 

only

 

the

 

ones

 

you

 

think

 

are

 

weak.

 

The

 

clock

 

circuits

 

of

 

the

 

device

 

are

 

powered

 

by

 

a

 

type

 

Ni

Cd

 

HA

 

35

 

storage

 

battery

 

and

 

it

 

is

 

continuously

 

charged

 

by

 

the

 

AA

 

batteries,

 

therefore

 

the

 

clock

 

time

 

is

 

held

 

and

 

resetting

 

the

 

time

 

is

 

unnecessary

 

between

 

battery

 

changes.

 

If

 

you

 

do

 

not

 

intend

 

to

 

use

 

the

 

device

 

for

 

a

 

long

 

period

 

of

 

time,

 

remove

 

the

 

batteries

 

and

 

store

 

them

 

in

 

a

 

cool

 

and

 

dry

 

place.

 

Do

 

not

 

apply

 

heat

 

to

 

the

 

batteries,

 

or

 

an

 

internal

 

short

 

circuit

 

may

 

occur.

 

Dispose

 

of

 

spent

 

batteries

 

immediately

 

in

 

an

 

environmentally

 ‐ 

safe

 

way.

 

The

 

batteries

 

and

 

charging

 

appliances

 

have

 

their

 

own

 

Instructions

 

for

 

use,

 

we

 

suggest

 

you

 

study

 

them

 

and

 

follow

 

manufacturers’

 

guidelines.

 

In

 

case

 

you

 

do

 

not

 

have

 

a

 

infrared

 

communication

 

adapter

 

or

 

a

 

built

in

 

infrared

 

in

 

your

 

PC,

 

connect

 

the

 

infrared

 

communication

 

adapter

 

to

 

your

 

PC

 

and

 

do

 

the

 

setting.

 

If

 

you

 

find

 

it

 

necessary,

 

ask

 

for

 

the

 

help

 

of

 

your

 

system

 

supervisor

 

who

 

is

 

responsible

 

for

 

your

 

computer.

 

Allow

 

the

 

infrared

 

communication

 

in

 

your

 

PC.

 

Then

 

if

 

the

 

device

 

is

 

within

 

1

 

m

 

from

 

the

 

infrared

 

adapter,

 

the

 

computer

 

will

 

get

 

into

 

connection

 

with

 

the

 

device

 

via

 

the

 

software.

 

To

 

transmit

 

data,

 

it

 

is

 

necessary

 

to

 

use

 

the

 

Medexpert

 

TensioWin™

 

program,

 

of

 

course.

 

Содержание CBPM24

Страница 1: ......

Страница 2: ...2...

Страница 3: ...Installing the Device 11 2 4 Operations Instructions 12 2 4 1 Functions of the button on the device 12 2 4 1 1 One short push of the button 12 2 4 1 2 Two short pushes on the button 13 2 4 1 3 Three...

Страница 4: ...ate measurement frequencies can be set for the active daytime passive night time and for a third special period Four different types of blood pressure measuring plans with different measuring frequenc...

Страница 5: ...ir respective companies 1 1 Contents of the manual This manual helps you in setting up and starting to use the Medexpert CBPM24 device Attention Before first use please read and understand this docume...

Страница 6: ...5 7 Budapest H 1037 Hungary Phone 36 1 250 4490 Fax 36 1 433 3795 Web www medexpert hu E mail arterialcare medexpert hu 1 4 General Information warnings and precautions We strongly suggest that you c...

Страница 7: ...fied service Only use with cuffs supplied by Medexpert Ltd Use of cuffs supplied by a third party can lead to erroneous measurement results Confirm blood pressure measurement with auscultation when er...

Страница 8: ...2 The Medexpert CBPM24 device 2 1 Explanation of symbols 1 Name of the device 2 Function button Offering five menu options see section 2 4 1 3 Command symbols see section 2 4 1 4 LCD display 5 Air con...

Страница 9: ...1 The classification of the protection against electric shock Classification patient s side CF 12 Calling the attention to read thoroughly the present User s Manual 13 Certification mark guaranteeing...

Страница 10: ...batteries 3 different cuffs Medexpert TensioWin software on CD User manual IrDA adapter For the 3 different size cuffs the dimensions are Bladder Dimensions Sleeve Dimensions Arm Circumference Cuff 01...

Страница 11: ...ore the clock time is held and resetting the time is unnecessary between battery changes If you do not intend to use the device for a long period of time remove the batteries and store them in a cool...

Страница 12: ...al will be between 5 4V 4 4V The nominal potential is 4 8V If the voltage is under 4 4 V the batteries need replacing The replace battery message will be displayed If long life batteries are used to p...

Страница 13: ...e stores all the measured data including the date and exact time 128 96 PUL 68 At any time during a reading the patient can terminate a reading by pressing once the single button A termination symbol...

Страница 14: ...ill be continued OFF 2 4 2 Data transmission The device downloads all the stored data to the physician s PC via infrared communication The information loaded consists of the systolic and diastolic blo...

Страница 15: ...as interrupted due to the weakness of the battery 31 The cuff is not connected to the device 32 The cuff tube is broken or something got into the tube e g water 33 The cuff or device is leaking 34 The...

Страница 16: ...ff the tube of the cuff should be inserted into the black opening on the left side of the device Attention Please take care of the connection of the cuff because it should not be too loose it should n...

Страница 17: ...Hg Static accuracy 3 mmHg or 2 of the measured value Measuring accuracy Systolic 94 out of 99 comparisons were within 5 mmHg 95 in case of 33 out of 33 patients 2 comparisons out of 3 were within 5 mm...