![MEDC DB4B Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/medc/db4b/db4b_technical-manual_1759409008.webp)
Where:
Signifies compliance with ATEX
II Signifies suitability for use in surface industries
2 Signifies suitability for use in a zone 1 area
G Signifies suitability for use in the presence of gases
Gas & Dust (GD) certified units
Certified to EN60079-0, EN60079-1, EN60079-7 and EN60079-31
Ex d IIIC unit (ATEX certification No. Baseefa13ATEX0231X)
Ex d IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP6X
Ex de IIIC unit (ATEX certification No. Baseefa13ATEX0233X)
Ex de IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP65/66*
*depending on outer flare type
See special conditions for safe use for ambient temperature ranges and T-ratings.
The ATEX certificate and product label carry the ATEX group and category marking:
II 2 GD
Where:
Signifies compliance with ATEX
II Signifies suitability for use in surface industries
2 Signifies suitability for use in a zone 1 area
G Signifies suita bility for use in the presence of gases
D Signifies suitability for use in the presence of dust
These units also have the following approvals:
Ingress protection: Ex d & Ex e terminal chambers - IP66 & IP67 to IEC60529
DNV Type approved. Approved according to IEC60945: Maritime navigation and radio communication equipment
and systems.
The equipment is classed as exposed.
Minimum compass safe distance is 5m.
06/17
© Eaton MEDC Ltd 2017