P/N 5011, V/05/28/2019

 

 

 

 

 

Electro Flo

®

 

5000 

Airway Clearance System 

User Manual

 

 

www.medsystems.com

 

Rx only

 

U.S. Patent No: US 8,777,880 B2 

Canadian Patent No: 2,804,531 

Made in the USA 

 

Содержание Electro Flo 5000

Страница 1: ...P N 5011 V 05 28 2019 Electro Flo 5000 Airway Clearance System User Manual www medsystems com Rx only U S Patent No US 8 777 880 B2 Canadian Patent No 2 804 531 Made in the USA ...

Страница 2: ...Electro Flo 5000 User Manual P N 5011 V 05 28 2019 Page Intentionally Left Blank ...

Страница 3: ...Contraindications 6 Safety Instructions 7 Electro Flo 5000 System Description 8 Self Administrator Personalized CPT 10 Operating Instructions 11 Step 1 Setup 11 Step 2 Treatment 13 Step 3 Shutdown 17 Cleaning Instructions 18 Maintenance 19 Disposal 19 Repairs 20 Warranty 21 Operating Environment 22 Specifications 22 Federal law restricts this device to be sold by or on the order of a physician or ...

Страница 4: ... that bring attention to specific statements WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or failure or damage of the device ...

Страница 5: ...00 System targets and loosens thick sticky mucus so that it may be cleared by huffing coughing and or suction Gravity helps ensure effective outcomes by using postural drainage positions to aid in moving mucus from the lungs up to the throat for clearance The Electro Flo 5000 Is designed for convenient personalized Chest Physiotherapy CPT May be self administered over individual lobes Is automated...

Страница 6: ... Electro Flo 5000 should not be used on patients who have severe calcium deficiencies or severe osteoporosis CAUTION The Electro Flo 5000 should not be used on patients who Have just eaten or are vomiting Have acute asthma or tuberculosis Have brittle bones broken ribs or severe osteoporosis Are bleeding from the lungs or coughing up blood Are experiencing intense pain Have increased pressure in t...

Страница 7: ...mmerse the unit in any liquid Product is to be used only as described in this manual and only as prescribed by a physician Inspect power cord and unit prior to use Do not use this product if any damage has occurred to power cord or any part of the system Do NOT insert any object into any opening on the system Always observe ALL warnings cautions and notes listed in this manual Information regardin...

Страница 8: ...lowing assemblies Control Box Power Head Carrying Case User Manual Accessory Self Administrator Strap The power and speed of percussion may be increased by turning the knobs clockwise There are 5 power settings and 6 speed settings making 30 combinations available for individual percussive needs Electro Flo 5000 Control Box and Power Head ...

Страница 9: ...er cord to connect the Control Box to an outlet and a 6 foot cord between the Control Box and the Power Head Electro Flo 5000 Control Panel Green Light POWER ON Blue Light SPEED RATE The power switch is located on the back of the unit on the lower right side ON and OFF Switch ...

Страница 10: ...y on their back unassisted and precisely where needed for immediate relief The Self Administrator The Self Administrator can be used by anyone with manual dexterity It has adjustable straps that can be adjusted to fit anyone s reach and for the treatment position being used Adjustable Straps Refer to MED SYSTEMS website for a demonstrational video of percussion treatment with the Self Administrato...

Страница 11: ...such as tissues pillows and towels b Remove equipment from carrying case and set up on a stable horizontal surface c Before plugging the unit in fully turn both knobs counter clockwise on the Control Panel d Unit has a three pronged Type B plug Plug the unit DIRECTLY into a properly grounded three pronged 120 Volt NEMA 5 15 receptacle ...

Страница 12: ... logo away from you f Open the Velcro closure and insert the Electro Flo 5000 Power Head as shown Placing the bottom of the Power Head in first will help with insertion It will be a snug fit g Tighten the Velcro closure securely CAUTION The cooling fan must be running to ensure successful cooling of the percussor Power Head If the cooling fan is not operating unplug and contact MED SYSTEMS for rep...

Страница 13: ...y assume a postural drainage position Techniques and settings may vary with each treatment Follow Postural Drainage Therapy guidelines as directed by your physician b Turn on Unit Press the upper part of the switch on the back of the Control Box to turn the unit ON The green indicator light will come on the Control Panel showing power is on and the fan is running The unit may cycle once This is no...

Страница 14: ...ower slow speed percussive action The blue light will blink at the speed rate of percussion f Adjust the Electro Flo 5000 Control Panel s power and speed settings to desired positions g Pressing against area being treated while applying pressure to the top cover will multiply the applied force and intensify the treatment Electro Flo s Force Multiplying Technology is activated when pressure is appl...

Страница 15: ...your hand or fingers h Treat each area to be drained for approximately 3 minutes i You may use the Self Administrator to reach lobes on the back or front j You can leave the Power Head in the Self Administrator to easily apply to the front of the chest Take deep breaths throughout the treatment Coughing is a normal result and a benefit of percussion Limit percussion to 20 minutes maximum per sessi...

Страница 16: ...s for a hands free treatment NOTE If the Power Head slips out of the Self Administrator during treatment pulling the straps toward the chest will correct its position CAUTION Avoid using the unit in a dusty environment or laying the Power Head on a blanket as the lint from the blanket may be drawn in by the fan and damage the unit ...

Страница 17: ...ut allow the unit to cool with the fan running b If using the Self Administrator remove the Power Head from the strap and place it on a lint free surface for COOL DOWN CAUTION Do not unplug or switch off the unit until COOL DOWN is complete c To turn off the unit press the lower half of the power switch The GREEN LED will turn off and the fan will stop Unplug the power cord from the outlet ...

Страница 18: ...nd damage the system CAUTION DO NOT autoclave DO NOT gas sterilize with ETO DO NOT clean with aromatic hydrocarbons Self Administrator To disinfect use an alcohol pad or disinfectant wipe Clean by wiping down with cool water and mild detergent or hand wash and allow to air dry out of direct sunlight Clean Velcro area on straps using a comb or brush to remove any debris or dirt from the Velcro Carr...

Страница 19: ...pect the percussion fan vent regularly Use compressed canned air once a month or as needed to clean and remove lint from the fan located in the Power Head Spray air onto the fan opening following usage directions on the can CAUTION Do not insert extension tube into the opening as is it might damage the fan Disposal Please dispose of your retired percussor by contacting your local landfill and requ...

Страница 20: ...ugged in and the power is switch on Show a blinking blue light when power is turned above the Stand By position Have percussive action with a blinking blue light and running fan Or has a cracked or broken part 3 For any of the above criteria please contact MED SYSTEM Customer Service for processing your return at the following numbers U S Toll Free 800 345 9061 Outside U S 858 483 9671 4 MED SYSTE...

Страница 21: ...te This warranty does not cover ordinary wear and tear arising from the normal use of the product The user of this product shall have the sole responsibility for any malfunction which results from improper use The following conditions will cause the warranty to be null and void Plugging the unit into an outlet that supplies more than 120 VAC Submersing the unit in water Operating the unit in an en...

Страница 22: ...l Equipment Model Model 5000 Electrical Classification Type BF Patient Contact Allowed Degree of Protection Against Water Ingress Ordinary IPX0 Operating Input Voltage 120 VAC Single Phase Supply Current Frequency 50 60 HZ Nominal Operating Voltage 120 VAC Single Phase Duty Cycle 20 minutes on 20 minutes off Information Regulatory CLASS II Electrical System Double Insulation Medical Equipment with...

Страница 23: ...Electro Flo 5000 User Manual P N 5011 V 05 28 2019 23 Page Intentionally Left Blank ...

Страница 24: ...P N 5011 V 05 28 2019 ISO 13485 Compliant Company 2631 Ariane Drive San Diego CA 92117 USA U S Toll Free 800 345 9061 Office 858 483 9671 Fax 858 483 9827 www medsystems com ...