INTERNAL LIGHT TUBES REPLACING
For the replacing of the light tubes proceed as follow:
-switch off the neon tubes using light switch.
-extract neon cover line pulling it out from a side
with a screwdriver.
-extract light tubes
Warning!
In order to access to electrical
components support you must
remove the frontal grid.
Light switch
GHIACCIO 120 - 180
INFORMATIONS ABOUT SERVICE
MALFUNCTIONS AND REMEDIES
Most of the functioning inconveniences are generally due to simple causes or to defective electrical
connections. These problems can usually be solved on the place.
The unit does not start
:
-
check that there is voltage at the wall socket;
-
check that the unit is properly plugged.
The internal temperature is not cold enough
:
-
check that the unit is not placed too close to any heating source or placed on to a continuosly air
flow action;
-
check that there is not too much ice on the evaporator: to enter the evaporator remove the ventilated
evaporator cover making attemption to not damage the motor fans.
-
check temperature setting.
-
check that the condenser is not blocked by dirt;
The unit is noisy
:
-
check that all the bolts and nuts are properly fasten;
-
check that the unit is placed on an even surface;
-
check if any pipe or fan is in contact with any other part of the body.