MED Associates ENV- 112CM Скачать руководство пользователя страница 3

 

 

 

- ii -

 

DOC-050 Rev 1.4 Copyright © 2017 

 

Table of Contents

 

Chapter 1 | Introduction

 ................................................................................................ 1

 

Specs

 ............................................................................................................................................... 1 

Chapter 2 | Connections

 ................................................................................................ 2

 

Operate Connector

 ........................................................................................................................ 2 

Response Connector

 ..................................................................................................................... 2 

*Optional Lever Position Connector

 ........................................................................................... 2 

Chapter 3 | Adjustable Tensioner

 ................................................................................ 3

 

Chapter 4 | Maintenance

 ............................................................................................... 3

 

Cleaning

 .......................................................................................................................................... 3 

Cleaning Supplies/Tools

 ............................................................................................................... 3 

Instructions

 .................................................................................................................................... 4 

Appendix A | Contact Information

 ............................................................................... 5

 

 

Содержание ENV- 112CM

Страница 1: ...for research RETRACTABLE RESPONSE LEVER ENV 112CM PRODUCT MANUAL DOC 050 Rev 1 4 Copyright 2017 All Rights Reserved Med Associates Inc P O Box 319 St Albans Vermont 05478 Phone 802 527 2343 Fax 802 52...

Страница 2: ...i DOC 050 Rev 1 4 Copyright 2017 Med Associates Inc notes...

Страница 3: ...apter 1 Introduction 1 Specs 1 Chapter 2 Connections 2 Operate Connector 2 Response Connector 2 Optional Lever Position Connector 2 Chapter 3 Adjustable Tensioner 3 Chapter 4 Maintenance 3 Cleaning 3...

Страница 4: ...V 112CM permits placement just 2 1cm above the grid floor and can be raised as needed with chamber filler panel inserts This lever is designed to work with ENV 007 ENV 008 and ENV 009 series chambers...

Страница 5: ...n Function Wire Color 1 28 Volt Ground Black 2 Extend Retract Lever White 3 28 Volts Red Response Connector Response connects to any available Input on a Standard MED Connection Panel via an included...

Страница 6: ...done once a week or once a month based on use to reduce buildup of dander dust or debris which can lead to unreliable operation and response detection Humid environments may require more frequent clea...

Страница 7: ...of lever 2 Using a 1 Philips screwdriver remove the 4 screws 2 on each side shown below 3 Slide the case backwards making sure not to pull completely off as there are wires connecting the circuit boar...

Страница 8: ...4 again to blow out any remaining debris 7 Slide the case forward and reattach using the 4 screws removed in step 2 Reinstall lever in chamber APPENDIX A CONTACT INFORMATION Please contact Med Associ...

Отзывы: