Electromagnetic flow Sensor 

mag-flux

 F5

 

 

__   

Technical Data 

 

Application field

 

see page 1 

Measuring principle 

pulsed constant field (DC) 
pulsed alternating field (AC) 

Inlet

 

 

Nominal diameter metering tube 

Measuring range 

 

Constant field 

Alternating field 

2 mm (0,078”) 

5 - 110 l/h 

3 - 110 l/h 

4 mm (0,156”) 

25 - 450 l/h 

15 - 450 l/h 

8 mm (0,312”) 

100 - 1800 l/h 

60 - 1800 l/h 

12 mm (0,47”) 

200 - 4000 l/h 

120 - 4000 l/h 

Measuring accuracy 

 

Error of measurement 

± 0,5 % of measured value 
 0,25 m/s to 10 m/s 

Repeat accuracy 

± 0,15 % of measured value 
 0,25 m/s to 10 m/s 

Operational conditions

 

 

Mounting position 

vertical or horizontal 

Max. operating temperature 

150°C / 302°F 

Pressure limits 

25 bar/ 362,5 psi 
higher upon request 

Temperature 

Max. pressure 

°C 

°F 

Bar 

Psi 

0 - 50 

32 -122 

10 

145 

60 

140 

8,5 

123 

70 

158 

7,5 

109 

80 

176 

6,5 

94 

90 

194 

5,5 

80 

100 

212 

4,5 

65 

110 

230 

3,8 

55 

Pressure/temperature limits with 

PVDF connections (DIN 8062) 

120 

248 

3,0 

44 

Protection class 

IP 67/IP 68 

Minimum conductivity 

·

 

with constant field 

·

 

with alternating field

 

 
> 10 

μ

S/cm 

> 0,1 

μ

S/cm

 

Specifications

 

 

Design 

Fully-welded steel fitting with cover 

made of aluminium 

Weight 

approx. 3 kg 

Cable inlet 

·

 

with constant field 

·

 

with alternating field

 

 
2 x M 16 x 1,5 / 2 x ½” NPT 
3 x M 16 x 1,5 / 3 x ½” NPT 

Material 

·

 

Metering tube 

·

 

Sensor housing 

·

 

Process connection

 

 

Zirconium oxide 
Steel 
Stainless Steel, Hastelloy, PVDF 

Electrodes 

·

 

Material 

·

 

Design 

 

Platinum 99,9%, sintered 
Flat electrode 

 

 

__   

Ordering data 

 

 

 
 

 
 

 
 

 
 

 
 

 

Electromagnetic flow Sensor

mag-flux

 F5

MAG 5 6 1 - 0

0 -

0

Measuring principle

• alternating field

3

• constant field

4

Nominal diameter of metering tube

• 2 mm

D

• 4 mm

E

• 8 mm

F

• 12 mm

G

Process connection

• G 1/2, mat.No. 1.4571

A

• G 1/2, HC4 (mat.No. 2.4610)

B

• G 1/2, PVDF with HC4- earthing rings (mat..No. 2.4610) 

C

• G 1/2, Titanium

S

• NPT 1/2", mat.No. 1.4571

D

• NPT 1/2", HC4 (mat.No. 2.4610)

E

• NPT 1/2", PVDF with HC4- earthing rings (mat.No. 2.4610) 

F

• DN 15 PN 25 DIN 2501, mat.No. 1.4571

H

• DN 15 PN 25 DIN 2501, HC4 (mat.No. 2.4610)

J

• DN 15 PN 25 DIN 2501, 

K

   PVDF with HC4- earthing rings (mat.No. 2.4610) 
• 1/2" Tri-Clamp, mat.No. 1.4571

L

• 1" Tri-Clamp, mat.No. 1.4571

N

• 1/2" ANSI B16.5 150 RF, mat.No. 1.4571

Q

• 1/2" ANSI B16.5 150 RF, 

T

   PVDF with HC4- earthing rings (mat.No. 2.4610) 
• other connections/ materials

Z

Gasket material

• EPDM

2

• Kalrez

3

Wall mount

• without

0

• with

1

Screwed gland

• M16 x 1,5

C

• NPT 1/2"

B

Degree of protection

• IP 67 / NEMA 5

B

• IP 68 / NEMA 6 mit 5m firmly connected cable

C

• IP 68 / NEMA 6 mit 10m firmly connected cable

D

Further designs

• Measuring range < 10 l/h

A11

• TAG plate inscription in english

B11

• with 3-point calibration certificate

B06

• with 6-point calibration certificate

B07

• Silicone-free materials

Y04

• TAG plate stainless steel

Y17