installation
&
care
instructions
REVISION: 04/2018 | page 3 of 4
AquaJet Pre-Rinse Products
Cont’d...
1.3 Securely fix the wall box to a solid wall surface using appropriate fixings. If possible, use the
screw caps supplied.
1.4 Connect the water hose to the water inlet/isolation valve using a thread
sealing compound or PTFE tape.
IMPORTANT: Do not twist valve during installation. To ensure a secure fit
use a 24mm spanner to hold the valve in place when tightening hose to valve.
1.5 Test unit for water leaks.
1.6 The gun hook is used to store the gun out of the way when not in use.
Install in an appropriate position that is convenient for the operator.