background image

NEED HELP? 1-800-832-2966

 

29 

 

WARRANTY 

2 YEAR LIMITED EMISSION-RELATED WARRANTY 

 

THIS ENGINE MEETS U.S. EPA EMISSION STANDARDS UNDER 40 CFR 1054.625 .The emission-related limited warranty is valid for two (2) years. 
Keep the purchase receipt and register your Generator for warranty at www.mechmarvels.com. QJ North America Inc. limits emission-related warranty 
repairs to authorized service centers for owners located within 100 miles of an authorized service center. For owners located  more than 100 miles from 
an authorized service center, QJ North America Inc. will, in its sole discretion, either pay for shipping costs to and from an authorized service center, 
provide for a service technician to come to the owner to make the warranty repair, or pay for the repair to be made at a loca l non-authorized service 
center. 
The provisions of this paragraph apply only for the contiguous states, excluding the states with high-altitude areas identified in 40 CFR part 1068, 
Appendix III. 
To exercise this warranty, DO NOT RETURN TO RETAILER. Instead, call Customer Service toll free at 1 -800-832-2966 (email address 
[email protected]) and you will be instructed on where to take the engine for warranty service. Take the generator and proof  of purchase (your 
receipt) to the repair facility recommended by the Customer Service Representative. The warranty does not extend to generator s damaged or affected 
by fuel contamination, accidents, neglect, misuse, unauthorized alterations, use in an application for which the product was not designed and any other 
modifications or abuse. 

 

1 YEAR LIMITED WARRANTY 

(30 Day Limited Warranty for Commercial and Rental Purpose) 

Generators are warranted to be free from defects in materials and workmanship for a period of 1 YEAR from date of original purchase. QJ North 
America Inc.. is not liable for any indirect, incidental or consequential damages from the sale or use of this product. Any implied warra nties are limited 
to 1 YEAR as stated, or as otherwise stated, in this written limited warranty. Some states do not allow the exclusion or limitation of incidental or 
consequential damages. Some states do not allow limitation on the length of an implied warranty.  QJ North America Inc. will repair or replace, at its 
discretion, any part that is proven to be defective in materials or workmanship under normal use during the 1 YEAR warranty per iod. Warranty repairs 
or replacements will be made without charge for parts or labor. Parts replaced during warranty repairs will b e considered as part of the original product 
and will have the same warranty period as the original product. This warranty gives you specific legal rights, and you may ha ve other rights that vary 
state to state. 

 

EMISSION CONTROL SYSTEM WARRANTY 

QJ NORTH AMERICA INC.

 

 

Your Warranty Rights and Obligations 

The California Air Recourse Board, U.S. EPA and QJ NORTH AMERICA INC. are pleased to explain the Emission 

Control System Warranty on your new outdoor power equipment engine. 

California 

In California, new spark-ignited small off-road equipment engines must be designed, built and equipped to meet 
the State’s stringent anti-smog standards. 

Other States, U.S. Territories 

In other areas of the United States, your engine must be designed, built and equipped to meet the U.S. EPA 

emission standards for spark-ignited engines at or below 19 kilowatts. 

All of the United States 

QJ NORTH AMERICA INC. must warrant the emission control system on your power equipment engine for the 

periods of time listed below provided there has been no abuse, neglect or improper maintenance of your power 

equipment  engine.  Where  a  warrantable  condition  exists,  QJ  NORTH  AMERICA  INC.  will  repair  your  power 

equipment engine at no cost to you including diagnosis, parts and labor. 

Your emissions control system may include parts such as: carburetors or fuel injection system, ignition system, 

catalytic  converters,  fuel  tanks,  valves,  filters,  clamps,  connectors,  and  other  associated  components.  Also, 

included may be hoses, belts, connectors, sensors, and other emission-related assemblies. 

Manufacturer’s Warranty Coverage: 

The emission control system is warranted for two years. If any emissions-related part on your engine is defective, 

the part will be repaired or replaced by QJ NORTH AMERICA INC. 

Owner’s Warranty Responsibility 

As  the  power  equipment  engine  owner,  you  are  responsible  for  the  performance  of  the  required  maintenance 
listed  in  your  owner’s  manual.  QJ  NORTH  AMERICA  INC.  recommends  that  you  retain  all  receipts  covering 

maintenance on your power equipment engine, but QJ NORTH AMERICA INC. cannot deny warranty solely for 

Содержание MM2350

Страница 1: ...and situation that may occur We reserve the right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT D...

Страница 2: ...smell the generator exhaust you are breathing CO But even if you cannot smell the exhaust you could be breathing CO CALIFORNIA PROPOSITION 65 WARNING This product or the exhaust from this product may...

Страница 3: ...el Rating 69 dB Run time 9hrs 50 load Gasoline Power Outlets 1 12V DC Outlet 2 120V Outlets Model MM4350 DF This unit is a Gasoline or Gasoline Propane Dual Fuel powered generator FEATURES 4000 Surge...

Страница 4: ...oad Gasoline 8350 Run Time 11hrs 50 load Gasoline 9350 Power Outlets 1 12V DC Outlet 4 120V Outlets 1 120V RV Outlet 1 120 240V Outlet For all MECH MARVELS Generators in this Manual Recommended Fuel t...

Страница 5: ...his Generator for the First Time 14 STARTING THE GENERATOR 17 STARTING THE GENERATOR USING PROPANE 17 Switching from Gasoline to Propane 17 Switching from Propane to Gasoline 17 Subsequent Use of this...

Страница 6: ...uation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a...

Страница 7: ...ns to operate this generator High Temperatures This generator produces heat when in operation Temperatures near the exhaust can exceed 150 Fahrenheit 65 Celsius Do not touch hot surfaces Observe all w...

Страница 8: ...phones sparks from these sources can trigger an explosion or fire It can collect in low areas or travel along the ground where an ignition source may be present Pressure can also build up in the conta...

Страница 9: ...NEED HELP 1 800 832 2966 9 In addition to the previously described safety information familiarize yourself with all safety and hazard notices on this generator...

Страница 10: ...are missing items call 1 800 832 2966 Monday Friday 9 AM 6 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List Set of 2 DC connector wires for charging 12 Volt...

Страница 11: ...Tank 7 Control Panel 8 Choke Used to start the engine 9 Air Filter Protects the engine by filtering dust and debris from the intake air 1 Recoil Starter Used to start the engine 2 Low Oil Shutdown Se...

Страница 12: ...40VAC Twist Lock Outlet 6 12V DC Connector 120VAC Duplex outlets are protected by 20A Circuit Breakers Each Duplex Outlet supports up to 2400 Watts 120VAC RV Outlet is protected by 30A Circuit Breaker...

Страница 13: ...e of the wheels by inserting the axle bolt and sliding a bushing in place 5 Carefully lift the rear of the generator and slide the assembly into the frame bracket Secure the axle bolt with the include...

Страница 14: ...oil in the engine crankcase Add the correct quantity of oil before operating this generator for the first time When replenishing oil for subsequent use of this generator always ensure that this genera...

Страница 15: ...ep 3 Ground the Generator Ground this generator by tightening the grounding nut against a grounding wire as illustrated in Figure 3 Number 6 AWG American Wire Gauge stranded copper wire is generally a...

Страница 16: ...rtain the CHOKE VALVE is at CHOKE CLOSED position The generator may be hard to start if CHOKE VALVE is at the RUN OPEN position Step 3 Ensure engine oil is full Step 4 Make sure GROUND TERMINAL is pro...

Страница 17: ...connect any electrical devices to the generator prior to starting the engine 1 Make sure the fuel valve is in the OFF position 2 Make certain the propane hose is properly connected to the generator 3...

Страница 18: ...generator AC Usage Electrical devices running on AC current may be connected according to their wattage requirements The rated running and surge wattage Model MM2350 DF Rated Running Surge Wattage 12...

Страница 19: ...d by multiplying the Voltage requirement 120 or 240 by the Amperage drawn Watts Volts x Amperes Or the wattage required by a device can be estimated by using the following chart see Figure 8 The chart...

Страница 20: ...nto this generator NOTE While this generator is running power is available from either the standard 120 Volt outlets or the 12 Volt DC outlet Both 120 Volts and 12V can be simultaneously drawn from th...

Страница 21: ...lug end of the wire to the 12V DC outlet on this generator 3 Start this generator 4 When disconnecting turn off the generator and always disconnect the wires from this generator first to avoid the ris...

Страница 22: ...commended Maintenance Schedule Each Use Every Month or Each 20 Hrs Every 3 Months or Each 50 Hrs Every 6 Months or Each 100 Hrs Every Year or Each 300 Hrs Engine Oil Check Level X Change X First Use X...

Страница 23: ...the pan and transfer to a container for recycling 4 Remove the oil fill cap dipstick 5 Re install the drain plug 6 Refill with the recommended oil and check the oil level 7 Wash your hands with soap...

Страница 24: ...after seating to compress the washer If re installing the original plug it will typically require less 8 Re attach the plug wire to the plug Torch Spark Plug Type Spark Plug Gap NGK Spark Plug Type E...

Страница 25: ...drain bolt and drain the gasoline into a suitable container by the fuel drain pipe c When all the fuel is drained tum the petcock to the OFF position and tighten the drain screw securely 3 Change the...

Страница 26: ...ESHOOTING Be sure that there is no fuel spilled around the spark plug spilled fuel may ignite Does not spark Consult authorized service center Consult authorized service center Check the Spark Plug Se...

Страница 27: ...RV 1 12VDC 8A 1 12VDC 8A Net Gross Weight 51 60Lbs 51 5 62Lbs 94 8 103 6lbs 95 2 105 4lbs Noise Level 69dB 69dB 70dB 70dB Unleaded Gasoline Unleaded Gasoline Unleaded Gasoline Unleaded Gasoline LPG 20...

Страница 28: ...A 1 120 240VAC 30A 1 12VDC 8A 1 12VDC 8A 1 12VDC 8A Net Gross Weight 196 0 204 8lbs 202 8 211 6lbs 204 8 213 6lbs Noise Level 73dB 73dB 73dB Unleaded Gasoline Unleaded Gasoline Unleaded Gasoline LPG 2...

Страница 29: ...America Inc will repair or replace at its discretion any part that is proven to be defective in materials or workmanship under normal use during the 1 YEAR warranty period Warranty repairs or replace...

Страница 30: ...is warranted for the warranty period stated above Any such part repaired or replaced under warranty will be warranted for the remaining warranty period 3 Any warranted part that is scheduled for repl...

Страница 31: ...ipe manifold b Air cleaner 3 Ignition system including a Spark plug b Ignition coil 4 Catalytic muffler assembly including a Muffler gasket b Exhaust manifold c Catalytic converter if available 5 Cran...