USER MANUAL
ME-650-VU/850-VU
ME-1000-VU/2000-VU
QUICK INSTALLATIONS & OPERATION
Inspection
Remove UPS from its package and inspect it for damage
before installation. If any damage is found, re-pack and
return the unit to the place of purchase.
Placement
Install the UPS in a protected area that is free of excessive
dust and has adequate air flow. DO NOT operate the UPS
where the temperature and humidity is outside the specific
limits.
Connect to Utility & Charging
Plug in the AC input cord to the wall outlet. For the best
results, suggest to charge the battery at least 4 hours
before initial use. The unit automatically charges ts
battery while connecting to the utility.
Connect the Loads
Plug in the loads to output receptacles on the rear panel of
the UPS. Simply turn on the power switch of UPS unit,
then devices connected to the UPS will be protected by
the UPS.
Connect Modem/Phone Line
Connect a single modem/phone line into surge-protected
“IN” outlet on the rear panel of the UPS unit. Connect from
“OUT” outlet to the computer with phone line cable.
Connect Communication Cable
To allow for unattended UPS shutdown/start-up and status
monitoring, connect the communication cable one end to
the USB port and the other to the communication port of
your PC. With the monitoring software installed, you can
schedule UPS shutdown / start-up and monitor UPS status
through PC.
Turning On/Off the Unit
Turn on the UPS unit by pressing the power switch. Turn
off the UPS unit by pressing again the power switch. You
may check the front LED indicators for the status.
Cold Start Function
When the UPS is off and there is no power utility, it’s still
possible to cold start the UPS unit to power the loads.
Monitoring Software Setup
Please follow steps below to install the software:
1. Insert the included CD into CD-ROM drive and then
follow the on-screen instructions. If there no screen
shows when inserting the CD after 1 minute, please
execute setup.exe for initiating software installation.
2. After computer restarts, the monitoring software will
appear as an orange plug icon
located in the
system tray.
TROUBLE SHOOTING
Problem
Possible Cause
Solutions
No LED display
on the front
panel.
Battery voltage is too low
Charge the UPS unit up
to 4
hours.
Battery failure.
Replace with the same
type of battery.
UPS always on
battery mode
Power cord loose
Re-plug the power cord.
Fuse is burned.
Replace the same type of
fuse
AC utility is too high or too low,
or there is a blackout
Normal condition
During power
failure, backup
time is shorten.
Overload of the UPS.
Remove some noncritical
load.
Battery voltage is too low.
Charge battery 4 hours or
more.
Battery defect due to high
temperature operation
environment, or improper
operation to battery.
Replace with the same
type of battery.
SPECIFICATIONS
MODEL
ME-650-VU ME-850-VU ME-1000-VU ME-2000-VU
INPUT
Capacity
650VA /
360W
850VA /
480W
1000VA /
600W
2000VA /
1200W
Voltage
110/120 VAC or 220/230/240 VAC
Voltage Range
81-145 VAC or 162-290 VAC
OUTPUT
AC Voltage Regulation
(Batt. Mode)
±10%
Frequency Range (Batt.
Mode)
50Hz or 60Hz ± 1 Hz
Transfer Time
Typical 2-6 ms, 10 ms max.
Waveform (Batt. Mode)
Simulated Sine Wave
BATTERY
Battery Type & Number
12 V/7 Ah x
1
12 V/9 Ah x
1
12 V/7 Ah x 2 12 V/9 Ah x 2
Typical Recharge Time
4-6 hours recover to 90% capacity
ALARM
Battery Mode
Sounding every 10 seconds
Low Battery
Sounding every second
Overload
Sounding every 0.5 second
Fault
Continuously sounding
PHYSICAL
Dimension, DXWXH
(mm)
287 x 100 x142
350 x 146 x
160
397 x 146 x
205
Net Weight (kgs)
4.25
4.9
8.0
11.5
ENVIRONMENT
Humidity
0-90 % RH @ 0- 40°C (non-condensing)
Noise Level
Less than 40dB
INTERFACE
USB Port
Windows2000/2003/XP/Vista/2008/7, Linux, Unix, and
MAC
* Product specifications are subject to change without further notice.
CAUTION:
NEVER connect a laser printer or scanner to the UPS
unit. This may cause the damage of the unit.