Meccanica Fadini Elpro 33 exp Скачать руководство пользователя страница 2

E

lpro   33 

exp

DESCRIPTION OF THE FUNCTIONS OF THE CONTROL PANEL FOR SWINGING GATES

CLR

ENT

"A"

"B"

DISPLAY

All the electrical connections are to be made as per the instructions and diagrams that follow. Supply the terminals 24-25 with
230 - 50 Hz single-phase voltage. The "red led" No. 1 goes on, this is the sign that the PC board is properly  supplied. The word
"BLOCCO" (Stop) is running from right to left in the display.

PARAMETERS AND MODES. SETTING PROCEDURE

Through the dispaly and by the programming buttons it is possible to access to and change all the functions of Elpro 33 exp.
The programs are devided into parameters (ie. variations of the times ) and modes (ie. the functions).)

PROGRAMMING BUTTONS

CLR 

TO CLEAR OR VISUALIZE THE PARAMETERS OR THE MODES

              (WHEN THE DISPLAY FLASHES)

         

TO INCREASE VALUES OF PARAMETERS OR CHANGE  MODES

"A"

         

TO  DECREASE VALUES OF PARAMETERS OR CHANGE MODES

"B"

ENT 

TO CHANGE (WHEN THE DISPLAY FLASHES)  AND THEN  TO

             CONFIRM  ALL THE  PARAMETERS AND MODES

= READING SCREEN =

To gain access to the parameters and modes press the button       , the display visualizes the word "CODE" and immediately afterwards
 “0” ie. one of the two possible options of the program:
                    - “0” program is stopped
                    - “1” access to program allowed, ie. to parameters and modes

To change from “0” to “1”, 

press the button       “ENT”    value “0” flashes. Change is allowed.

                                             press the button

         value “1” is displayed (flashing) .

                                             press the button       “ENT”    the value stops flashing. Change is confirmed.
                                             press the button 

         the first parameter “PR1A” is displayed.

                                                                                        Go on pressing the button and the following list of parameters and
                                                                                         modes appears in a sequence:

MODES:

 MOD9
 MOD8
 MOD7
 MOD6
 MOD5
 MOD4
 MOD3
 MOD2
 MOD1

PARAMETERS: 

PR10

 PR9C
 PR9A
 PR8
 PR7
 PR6
 PR5
 PR4
 PR3
 PR2
 PR1B
 PR1A

ABBREVIATIONS TO APPEAR
ON THE SCREEN
(DISPLAY)

YOU CAN GO DOWN THE

MENUE BY PRESSING

THE BUTTON:

FROM 

PR1A

 to 

MOD9

"A"

"B"

THIS DIRECTION UP BY

PRESSING THE BUTON:

This section explains how to change the parameters and modes:

                                             select the desired option and wait three seconds for the previously set value to appear.
                                             press the button

 “ENT”

    the value starts flashing, changing is allowed.

                                             press either                      or           to increase or decrease the previous value.

   press the button            “ENT”

    the value stops flashing, change is confirmed.

                                                        You can go back to the original menue options

"A"

"B"

To exit the program:

                                             press the button

    until “CODE” and soon afterwards “1” are displayed.

                                             press the button 

  “ENT”      value“1” starts flashing, ie. changing is allowed.

                                             press the buton

    value “0” is displayed  (flashing).

                                             press the button 

  “ENT”

    the value stops flashing, change is confirmed.

press the button                            gate status ie. operations to perform are diplayed in words

                                                                                                      (see the section "gate status on display")

- The button "CLR" allows to exit a parameter or mode without changing its value and, in case a value is displayed, to see which
   parameter or mode has been previously selected

.

"B"

"B"

"B"

Содержание Elpro 33 exp

Страница 1: ...TACT CLOSE N C CONTACT STOP RADIO CONTACT COMMON 24V ac OUTPUT ELECTRIC LOCK INDICATOR 24V 3W max 24V ac OUTPUT MAX LOAD 2 PAIRS PHOTOCELLS 1 RADIO RECEIVER N C SAFETY CONTACT COMMON FLASHING LAMP 230V 25W max 230V SINGLE PHASE SUPPLY VOLTAGE 17 18 19 20 21 22 23 24 25 NEUTRAL LIVE 3 4 3 4 PEDESTRIAN OPENING CONTACT ANY PULSE HELD ON FOR MORE THAN 2 SECONDS OPENS ONLY ONE GATE LEAF TOW CONSECUTIVE...

Страница 2: ...s allowed press the button value 1 is displayed flashing press the button ENT the value stops flashing Change is confirmed press the button the first parameter PR1A is displayed Go on pressing the button and the following list of parameters and modes appears in a sequence MODES MOD9 MOD8 MOD7 MOD6 MOD5 MOD4 MOD3 MOD2 MOD1 PARAMETERS PR10 PR9C PR9A PR8 PR7 PR6 PR5 PR4 PR3 PR2 PR1B PR1A ABBREVIATION...

Страница 3: ...n LED n 13 Mains Relay normally off it goes on during operation GATE STATUS INDICATION BY DISPLAY On the display it is possible to see the status of the gate ie the operation the system is performing by means of words running from right to left When the gate is OPEN or CLOSED semi automatic OPENING or CLOSING semi automatic OPEN or CLOSED automatic OPENING or CLOSING automatic STOPPED OBSTRUCTED i...

Страница 4: ...th the equipment 3 Bridge terminals 1 2 if you do not require any photocells 4 Should two sets of photocells be required these are to be series connected to terminals 1 2 contact normally closed In case they are installed parallel to each other cross install the receivers with the projectors receiver next to projector of the other set 5 Bridge terminals 3 6 if you do not require any keyswitch or p...

Отзывы: