Mec TriTask-150s Скачать руководство пользователя страница 3

MEC-Energietechnik GmbH 

OPERATING INSTRUCTIONS 

TriTask-150s 

Vers.: 08/2016 

Page 3 of 4 

 

III. Start charging: 

 
a) Plug in the power cable into the power socket. 
The charging process starts automatically and runs through the following three charging phases: 
 

1. charging phase: constant current (CC) 

This charging step is indicated by the 

red charge-control LED 

(4). 

During the constant current phase, the battery is being charged to 80% of its capacity. 
 

2. charging phase: constant voltage (CV)  

This charging step is indicated by the 

yellow charge-control LED 

(3). 

During the constant voltage phase the battery is being charged to its maximum capacity. 
 

3. charging phase: float charge / battery is fully charged 

This charging step is indicated by the 

green charge control LED 

(2). 

As soon as the battery has reached its full capacity, the charger switches into float-charge mode. The charger can 
now  be  disconnected  from  the  battery  (see  pt.  IV  disconnection  the  charger)  or  remain  at  the  battery  in  float- 
charge mode. This guarantees a full battery at any time and therefore an instant operational readiness. 
 

IV. Disconnect the charger from the battery:

 

 

a) Disconnect the charger from the mains supply; 
b) Disconnect the charger from the battery; 
 

 

Charging advice: 

  If the charger will be disconnected from the battery during the charging process, the charge current will be in-

terrupted immediately. In that case please disconnect the charger from the mains supply. For starting a new 
charging process please comply with the relevant points (see pt.I) 

  For increasing the lifetime of a battery please do not stop a charging process before the automatic switching 

to float charge mode (3

rd

 charging step). 

 

 

6.  Errors and Troubleshooting 

 

Red Power-LED lights, battery is connected but charging process does not start: 

 

- Check if the mains plug is correctly plugged in; 

 

- A defective or deep-discharged battery is connected 

 Battery must be disposed; 

 

 

Red Power-LED does not light: 

 

- Check if the mains-plug is connected properly; 

 

- Check if mains cable is defective; 

 

7.  Technical Data 

TriTask-150s Series 

Version 

12V / 6A 

12V / 8A 

12V / 10A 

24V / 5A 

Input (VAC) 

230V / 50Hz

 

Charging characteristic 

IU0U 

Charging current (A) 

10 

Output power max. (W) 

94 

125 

156 

156 

Temperature range 

0°C 

– 40°C 

Cooling 

Convection 

Fan 

Mains cable connection 

Fix mounted 

Charge connection 

Fix mounted DC-cable 

Certifications 

CE 

Dimensions / Weight 

180 x 110 x 36mm  /  ~800g 

Rec. battery capacity (Ah) 

18 - 75 

24 - 100 

30 - 125 

15 - 65 

MEC Art-No.: 

161-06602-100 

161-06802-100 

161-06103-100 

161-12502-100 

 
 
 
 
 

Отзывы: