5.1.3
RS485 Communications interface
This cable is provided to enable the use of the STIRLING ENGINE DATA VIEWER
software:
Figure 5.4 STRILING ENGINE DATA VIEWER
For details, please consult the Data Viewer User Manual MEC-WI-584.
Additionally, via the RS485 communication-bus, data can be provided to your
Application which can be used to help control the heat source in running the Engine
optimally and safe. Please contact TDSP for more information.
5.1.4
Head Thermocouples
Connect these two cables with connector to the two mating connectors of the two K-
type thermocouples that are incorporated into the engine head. The values provided
by these thermocouples are used as part of the Engine control and protection
algorithms.
5.1.5
Flow Meter
Connect this cable with connector to the provided HUBA 200.915101N (DN15) vortex
flow sensor, this sensor must be used to allow for measuring the coolant flow-rate.